Working Principle
A fan tray assembly inside a subrack dissipates heat for the subrack to ensure that the subrack
works effectively at a specified temperature. The fan tray assembly is located on the lower
part of a subrack. It blows air into the subrack, forming an air duct from bottom to top. Other
boards in the subrack are installed vertically. In other words, the boards are parallel to the air
duct. This design ensures reliable heat dissipation.
and ventilation system in the OptiX OSN 8800 T16.
Figure 4-23 Subrack heat dissipation and ventilation system
Front
The OptiX OSN 8800 T16 supports two fan speed modes, as described in
partitioned speed regulating function is available in Auto Speed Mode. It is recommended that
you operate fans in Auto Speed Mode by default.
Issue 01 (2016-03-10)
Side view
Air outlet
Air inlet
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Description
independently regulated.
Provides the hot swapping function for the fan tray assembly.
Reports alarms of the fans, and reports the in-service
information.
Checks and reports on the fan status.
Fan
Air filter
4 OptiX OSN 8800 Subrack
Figure 4-23
shows the heat dissipation
Table
4-41. The
60