Mitsubishi Electric G-50A Instruction Book page 10

Central controller
Hide thumbs Also See for G-50A:
Table of Contents

Advertisement

Collective operation switch
If this switch is pressed during the
operation, a whole group stop is
performed.
6 ADDRESS SETTING
7 FUNCTION SETTING
8 IP ADDRESS SETTING
BACK
2
Interlocked setting function
This function sets either single or
multiple indoor units, the
LOSSNAY or any other OA
processing unit that interlocking
operates, as units in the same
operation.
Refer to section "5. Initial settings
(page 25)" for detail of operations.
Required function for initial settings
The collective operation switch can be performed in the user setting mode for any screen.
(Excluding menu screen)
LAN changeover switch
Refer to section "5. Initial setting (page 25)" for
explanation of the operation of these switches.
LCD contrast adjustment knob
LAN status lamp
Orange LED indicates action and green LED indicates link.
Service LAN connector
Refer to section "5. Initial setting" for an explanation of this connector.
Rear side
Operation
panel
LAN (Ethernet) connector
6
7
8
VER.
.
3
4
5
User setting function
GROUP NO
NONE
INDICATE
INDICATE
1-1-2001
NONE
7
TEMP. UNIT
˚C
/ ˚F
The function selections of the dis-
play method and timer settings that
is displayed on the screen.
Refer to section "5. Initial settings
(page 25)" for detail of operation.
Ethernet
M-NET
POWER
A
B
S
12VDC
RS-232C connector
M-NET Transmission
line terminal
External input/output interface connector
DC power supply terminator
M-NET address setting
Function select setting
FUNCTION SETTING
ADDRESS SETTING
M-NET ADDRESS: 000
ON
OFF
Display, or sets, the controller M-
Sets the function of the controller.
NET address.
Refer to section "5. Initial setting
Refer to section "5. Initial setting
(page 25)" for a detailed expla-
(page 25)" for a detailed expla-
nation of operation.
nation of operation.
Required function for initial settings
Refrigerant monitor function
The unit addresses are displayed
for each refrigerant.
Refer to section "6. Maintenance
(page 36)" for detail of operation.
Start-up and maintenance functions
– 9 –
1 CN1
5
1
9
GND
RS232C
CN2
Refer to section "7. External input/output
function (page 38)" for the detail of op-
eration of these connectors.
IP address setting
IP ADDRESS SETTING
1 2 3 4 5 6 7 8
IP ADDRESS:
SUBNET MASK:
Sets the LAN IP address.
Refer to section "5. Initial setting
(page 25)" for a detailed expla-
nation of operation.
Malfunction log monitor
2002
16-04-2002
12 : 45
014 6602
(DETECT 014)
2002
05-04-2002
09 : 12
012 6607
(DETECT 012)
2002
A malfunction logging which can
store a maximum of 64 items that
can be monitored.
Refer to section "6. Maintenance
(page 36)" for detail of operation.
192.168.001.001
255.255.255.000