Cam; Diaphragm Assembly - ABB AV1 Operating Instructions Manual

Actuators & positioners
Hide thumbs Also See for AV1:
Table of Contents

Advertisement

Cam

Tools Required:

Diaphragm Assembly

5. Slide the I/P converter out from under the screws and remove it
from the housing.
6. Disconnect the two air lines from the I/P converter. When replac-
ing the I/P converter, remove the portion of the air line tubing that was
connected to the I/P converter or replace the tubing. If this is not
done, particles from the tubing can cause a blockage.
7. Reverse the preceding steps to install the new I/P converter.
NOTE: Item numbers reference Figure 9-3.
Flat-tip screwdriver.
Adjustable wrench.
Pliers.
1. Transfer the positioner from automatic to manual operation
(Section
5).
2. Remove the positioner cover by removing the two cover screws.
3. Remove the indicator screw (Item 51) and indicator (Item 19).
4. Hold and stop the cam shaft from rotating if it is not secured by
linkage or coupling. Using the adjustable wrench, remove the cam nut
(Item 30) and washer (Item 55).
5. Lift the cam from the cam shaft.
6. To replace the cam, determine which cam mounting hole (A, B or
C) is appropriate for the application, and set the cam on the shaft.
Make certain the star-shaped hole engages squarely on the shaft.
Refer to Figure
3-8
to align the cam.
7. Replace the cam washer and nut and tighten.
8. Set the indicator on the cam shaft and insert and tighten the
screw.
9. Transfer the positioner back to automatic operation
NOTES:
1.
Refer to
Section 9
2.
Item numbers in this procedure reference Figure
REPAIR AND REPLACEMENT
for diaphragm assembly kit numbers.
REPLACEMENT PROCEDURES
(Section
5).
9-3
or 9-4.
8 - 5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Av2Sv1121000

Table of Contents