This step requires a separate process, training, and license keys. Contact Hitachi
Vantara if the incorrect model arrives for replacement.
11. Navigate to Home > SMU Administration > Upgrade SMU to verify and, if
necessary, upgrade the embedded SMU to the latest SMU release.
12. Navigate to Home > Server Settings > Firmware Package Management to verify
and, if necessary, upgrade the new server to the latest SU release.
13. Navigate to Home > Server Settings > Configuration Backup & Restore, select the
desired backup file, and click restore to restore the system from that backup file.
14. Reboot the server.
15. Reconnect the data cables to the server.
Finalizing and verifying the replacement server configuration
The Fibre Channel (FC) link speed varies according to the server model. Use the
appropriate speed for your model.
HNAS 4040
HNAS 4060, 4080, and 4100
On the replacement server:
Note: The following steps show the FC link speed as 8 Gbps as an example.
Hitachi NAS Platform and Hitachi Unified Storage Series 4000 Hardware Reference
Finalizing and verifying the replacement server configuration
Model
4 Gbps
8 Gbps
Appendix A: Server replacement procedures
Fibre Channel link speed
97