Sign In
Upload
Manuals
Brands
Hitachi Manuals
Storage
G1000
Hitachi G1000 Manuals
Manuals and User Guides for Hitachi G1000. We have
6
Hitachi G1000 manuals available for free PDF download: User Manual, Hardware Manual
Hitachi G1000 User Manual (246 pages)
virtual storage platform
Brand:
Hitachi
| Category:
Storage
| Size: 3.1 MB
Table of Contents
Table of Contents
3
Preface
9
Intended Audience
10
Product Version
10
Release Notes
10
Document Revision Level
10
Changes in this Revision
10
Referenced Documents
10
Document Conventions
11
Convention for Storage Capacity Values
12
Accessing Product Documentation
12
Getting Help
13
Comments
13
1 Overview of Global-Active Device
15
About Global-Active Device
16
Global-Active Device Solutions
17
Fault-Tolerant Storage Infrastructure
17
Failover Clustering Without Storage Impact
18
Server Load Balancing Without Storage Impact
19
System Configurations for GAD Solutions
20
GAD and Global Storage Virtualization
23
About the Virtual ID
23
Monitoring GAD Status
24
GAD Status
24
GAD Status Transitions
25
Pair Status
26
I/O Modes
26
Relationship between GAD Status, Pair Status, and I/O Mode
27
Global-Active Device and Server I/O
28
Server I/O When the GAD Status Is Mirrored
29
Server I/O When the GAD Status Is Mirroring
29
Server I/O When the GAD Status Is Suspended
30
Server I/O When the GAD Status Is Blocked
31
Quorum Disk and Server I/O
31
I/O Stoppage Detected in the Counterpart System
32
I/O Stoppage Not Detected in the Counterpart System
33
GAD Pair Operations
33
Initial Copy and Differential Copy
34
GAD Components
35
User Interfaces for Global-Active Device Operations
36
Hitachi Command Suite
37
Command Control Interface
37
Configuration Workflow for Global-Active Device
37
2 System Requirements
39
Requirements and Restrictions
40
Interoperability Requirements
42
Volume Types that Can be Used for GAD
42
Dynamic Provisioning / Dynamic Tiering
44
Shadowimage
44
Limitations When Sharing GAD and Shadowimage Volumes
46
SI Operations and GAD Pair Status
46
GAD Operations and si Pair Status
49
Thin Image
50
Limitations for Using both GAD and Thin Image
51
Thin Image Operations and GAD Status
51
GAD Operations and Thin Image Pair Status
54
Use Cases for Pairing GAD Volumes with si or HTI
55
Data Retention Utility
55
GAD Status and I/O Allowance by Access Attribute
56
LUN Manager
57
Virtual Partition Manager
57
Volume Shredder
57
Performance Monitor
57
GAD I/O Added to Performance Monitor
58
Number of I/Os to the Port to be Added to Performance Monitor
59
3 Planning for Global-Active Device
61
Storage System Preparation
62
Planning System Performance
63
Hitachi Dynamic Link Manager
63
Planning Physical Paths
64
Determining the Required Bandwidth
64
Fibre-Channel Connections
65
Connection Types
66
Direct Connection
66
Connection Using Switches
67
Connection Using Channel Extenders
68
Planning Ports
69
Planning the Quorum Disk
70
Installation of the External Storage System
70
Relationship between the Quorum Disk and Number of Remote Connections
71
Suspended Pairs Depending on Failure Location (Quorum Disk Not Shared)
72
Suspended Pairs Depending on Failure Location (Shared Quorum Disk)
72
Response Time from the External Storage System
75
Planning GAD Pairs and Pair Volumes
76
Maximum Number of GAD Pairs
76
Calculating the Number of Cylinders
77
Calculating the Number of Bitmap Areas
77
Calculating the Maximum Number of Pairs
78
S-VOL Resource Group and Storage System: same Serial Number and Model
78
Calculating the Number of Available Bitmap Areas
78
4 Configuration and Pair Management Using CCI
81
Global-Active Device System Configuration
83
Primary Storage System Settings
84
Secondary Storage System Settings
85
CCI Server Configuration
86
Resource Group
86
External Storage System Settings
87
Workflow for Creating a GAD Environment
87
Initial State
88
Adding the External System for the Quorum Disk
88
Verifying the Physical Data Paths
89
Creating the Command Devices
90
Creating the Configuration Definition Files
91
Starting CCI
92
Connecting the Primary and Secondary Storage Systems
93
Setting the Port Attributes
93
Adding Remote Connections
95
Creating the Quorum Disk
97
Setting the Port Attributes for Connecting the External Storage System
97
Creating External Volume Groups
99
Creating External Volumes
101
Setting External Volumes as Quorum Disks
104
Setting up the Secondary System
106
Creating a Resource Group (P-VOL Not Registered to a VSM)
107
Creating a Resource Group (P-VOL Registered to a VSM)
108
Reserving a Host Group ID
109
Deleting the Virtual LDEV ID of the S-VOL
111
Reserving an LDEV ID for the S-VOL
112
Setting the Reservation Attribute on the S-VOL
113
Creating Additional Host Groups in a VSM
115
Creating a Pool
116
Creating the S-VOL
118
Adding an LU Path to the S-VOL
120
Updating the CCI Configuration Definition Files
121
Shutting down CCI
122
Editing CCI Configuration Definition Files
122
Restarting CCI
123
Creating the GAD Pair
123
Verifying the Virtual LDEV ID in the Virtual Storage Machine of the Secondary Site
123
Revising the Virtual LDEV ID in the Virtual Storage Machine of the Secondary Site
124
Creating a Global-Active Device Pair
125
Adding an Alternate Path to the S-VOL
127
5 Using Hitachi Command Suite to Set up Global-Active Device
129
Setting up a Global-Active Device Environment
130
About Global-Active Device Setup
130
Prerequisites for Global-Active Device Setup Using HCS
132
Select Primary and Secondary Storage Systems
132
Configuring Remote Paths
133
Configuring the Quorum Disk
134
Configuring Pair Management Servers
136
Configuring the Virtual Storage Machine
137
Monitoring and Managing Global-Active Device Pairs
138
Allocating Global-Active Device Pairs
138
Allocating Global-Active Device Pairs Using Existing Volumes
140
Adding Redundancy to Open-Allocated Volumes
142
Checking Global-Active Device Pair Status
144
Protecting Global-Active Device Pairs
145
Monitoring Global-Active Device Pair Performance
146
Unallocating Global-Active Device Pairs
147
Unallocating Individual Global-Active Device Volumes
148
Recovering from Global-Active Device Failures
149
About Global-Active Device Failures
150
Recovering from HBA-Related Host Path Failures
150
Discontinuing a Global-Active Device Environment
151
6 Disaster Recovery of Global-Active Device
153
Failure Locations
155
Sims Related to GAD
157
Pair Condition before Failure
159
Pair Condition and Recovery: Server Failures
160
Pair Condition and Recovery: Path Failure between the Server and Storage System
160
Recovering from a Path Failure between the Server and Primary System
161
Recovering from a Path Failure between the Server and Secondary System
162
Pair Condition and Recovery: P-VOL Failure (LDEV Blockade)
163
Recovering the P-VOL (Pair Status: PAIR)
164
Pair Condition and Recovery: S-VOL Failure (LDEV Blockade)
167
Recovering the S-VOL (Pair Status: PAIR)
168
Pair Condition and Recovery: Full Pool for the P-VOL
171
Recovering a Full Pool for the P-VOL (Pair Status: PAIR)
172
Pair Condition and Recovery: Full Pool for the S-VOL
174
Recovering a Full Pool for the S-VOL (Pair Status: PAIR)
175
Pair Condition and Recovery: Path Failure from the Primary to Secondary System
176
Recovering Paths from the Primary to Secondary System (Pair Status: PAIR)
177
Pair Condition and Recovery: Path Failure from the Secondary to Primary System
179
Recovering Paths from the Secondary to Primary System (Pair Status: PAIR)
180
Pair Condition and Recovery: Primary System Failure
181
Pair Condition and Recovery: Secondary System Failure
183
Pair Condition and Recovery: Path Failure from the Primary to External System
185
Recovering the Path from the Primary to External System (Pair Status: PAIR)
186
Pair Condition and Recovery: Path Failure from the Secondary to External System
188
Recovering the Path from the Secondary to External System (Pair Status: PAIR)
189
Pair Condition and Recovery: Quorum Disk Failure
191
Recovery of the Quorum Disk (Pair Status: PAIR)
192
Pair Condition and Recovery: External System Failure
197
Pair Condition and Recovery: Other Failures
198
Recovery Procedure for GAD Pair Suspension Due to Other Failures
199
Recovering the Storage Systems from a Primary Site Failure (External System at Primary Site)
200
Reversing the P-VOL and S-VOL
203
Resolving Failures in Multiple Locations
204
7 Planned Outage of Global-Active Device Storage Systems
205
Planned Power Off/On of the Primary Storage System
206
Powering off the Primary Storage System
206
Powering on the Primary Storage System
206
Planned Power Off/On of the Secondary Storage System
206
Powering off the Secondary Storage System
206
Powering on the Secondary Storage System
207
Planned Power Off/On of the External Storage System (I/O at Primary Site)
207
Powering off the External Storage System (I/O at Primary Site)
207
Powering on the External Storage System (I/O at Primary Site)
208
Planned Power Off/On of the External Storage System (I/O at Secondary Site)
209
Powering off the External Storage System (I/O at Secondary Site)
209
Powering on the External Storage System (I/O at Secondary Site)
209
Planned Power Off/On of the Primary and Secondary Storage Systems
210
Powering off the Primary and Secondary Storage Systems
210
Powering on the Primary and Secondary Storage Systems
210
Planned Power Off/On of the Primary and External Storage Systems
211
Powering off the Primary and External Storage Systems
211
Powering on the Primary and External Storage Systems
211
Planned Power Off/On of the Secondary and External Storage Systems
212
Powering off the Secondary and External Storage Systems
212
Powering on the Secondary and External Storage Systems
213
Planned Power Off/On of All GAD Storage Systems
213
Powering off the Primary, Secondary, and External Storage Systems
213
Powering on the Primary, Secondary, and External Storage Systems
214
8 Data Migration and Volume Reuse
217
Workflow for Data Migration
218
Reusing Volumes after Data Migration
219
Reusing a Volume that was an S-VOL
219
Reusing a Volume that was a P-VOL
220
9 Troubleshooting
221
General Troubleshooting
222
Troubleshooting Related to Remote Path Status
223
Error Codes and Messages
227
Troubleshooting for CCI
227
SIM Reports of GAD Operations
236
Procedure for Recovering Pinned Track of a GAD Volume
236
Calling Hitachi Data Systems Customer Support
237
A Correspondence between GUI Operations and CLI Commands
239
Correspondence between GUI Operations and CCI Commands
240
Advertisement
Hitachi G1000 Hardware Manual (208 pages)
Virtual Storage Platform
Brand:
Hitachi
| Category:
Storage
| Size: 7.65 MB
Table of Contents
Table of Contents
3
Preface
7
Changes in this Revision
8
Intended Audience
8
Product Version
8
Release Notes
8
Safety and Environmental Information
8
Document Conventions
9
Related Documents
9
Conventions for Storage Capacity Values
10
Accessing Product Documentation
11
Comments
11
Getting Help
11
1 Introduction
13
System Overview
14
Features
14
High Performance
15
Scalability
16
Flexible Connectivity
17
High Reliability
17
High Flexibility
17
Nondisruptive Service and Upgrades
19
High Temperature Mode
19
Economical and Quiet
21
Hardware Overview
21
Controller Chassis
29
Controller Components
30
Front-End Director
32
Supported Connections and Protocols
33
Flexible Front-End Director Installation
35
Supported Speeds and Cable Lengths
38
Drive Chassis
39
Cache Memory
43
Memory Operation
44
Data Protection
44
Cache Capacity
45
Shared Memory
45
Cache Flash Memory
48
CFM Operation
48
Cache Flash Memory Capacity
48
2 Hardware Architecture
51
System Architecture Overview
52
Hardware Architecture
52
VSP G1000, VSP G1500, and VSP F1500 RAID Implementation
53
Array Groups and RAID Levels
53
Raid 1
54
Raid 5
55
Raid 6
58
LDEV Striping Across Array Groups
59
CU Images, Lvis, and Logical Units
61
CU Images
61
Logical Volume Images
62
Logical Units
62
Mainframe Operations
62
Mainframe Compatibility and Functionality
63
Mainframe Operating System Support
63
Mainframe Configuration
63
Systems Operations
64
Compatibility and Functionality
64
Systems Host Platform Support
64
System Configuration
65
Host Modes and Host Mode Options
65
Device Manager - Storage Navigator
66
3 Safety Requirements
69
General Safety Guidelines
70
Work Safety Guidelines
70
Warning about Moving Parts
71
Electrical Safety Guidelines
71
4 Site Preparation
73
Safety Requirements
74
Responsibilities
74
User Responsibilities
74
Hitachi Data Systems Responsibilities
74
Site Preparation Checklist
75
General Site Requirements
77
Equipment Clearances
77
Equipment Weight
77
System Storage Requirements
78
Data Center Requirements
78
Operational Requirements
79
System Specifications and Requirements
79
Mechanical Specifications
80
Electrical Specifications
81
Grounding
82
Power Connection
82
Environmental Specifications
83
Component Weight, Heat, Airflow, and Power Consumption
84
Airflow
88
Equipment Noise
88
Power Connection Diagrams
89
UPS Power Connection
92
Data Connection Diagrams
93
Long Cable Connections
97
Port Configurations
104
5 Power On/Off Procedures
107
Safety and Environmental Information
108
Power Control Panel
108
System Idle Mode
109
Normal Power On/Off Procedures
110
Power on Procedures
110
Power off Procedures
111
Emergency Power Off/On Procedures
112
Emergency Power off Procedure
112
Power on Procedure after Emergency Power off
112
Battery Backup Operations
112
Cache Backup Batteries
113
Battery Life
114
Storing the System
114
6 Troubleshooting
117
Getting Help
118
Solving Problems
118
Service Information Messages (SIM)
118
A Specifications
121
Storage System Specifications
122
Mechanical Specifications
127
Electrical Specifications
127
Environmental Specifications
129
PDU Specifications
131
B System Option Modes
133
System Option Modes
134
SOM Details
176
Details for SOM 15
176
Details for SOM 122
177
Details for SOM 269
179
Details for SOM 467
179
Details for SOM 729
179
Details for SOM 784
179
Details for SOM 803
180
Details for SOM 855
180
Details for SOM 897, SOM 898, and SOM 901
180
Details for SOM 901
181
C Regulatory Compliance
183
Regulatory Compliance
184
US FCC Notice
186
Electronic Emissions Testing
186
European Declaration of Conformity
187
Notice of Export Controls
187
China Rohs
187
Hazardous and Toxic Substances
188
Disposal
188
Recycling
188
Electronic Emissions Certificates
188
Glossary
193
Index
205
Hitachi G1000 Hardware Manual (194 pages)
Brand:
Hitachi
| Category:
Network Storage Server
| Size: 7.72 MB
Table of Contents
Table of Contents
3
Preface
7
Safety and Environmental Information
8
Intended Audience
8
Product Version
8
Release Notes
8
Changes in this Revision
8
Related Documents
9
Document Conventions
9
Conventions for Storage Capacity Values
10
Accessing Product Documentation
11
Getting Help
11
Comments
11
VSP G1000, VSP G1500, and VSP F1500 Overview
13
System Overview
14
Features
14
High Performance
15
Scalability
16
Flexible Connectivity
17
High Reliability
17
High Flexibility
17
Nondisruptive Service and Upgrades
18
High Temperature Mode
19
Economical and Quiet
21
Storage System Hardware Overview
23
Storage System Configurations and Model List
25
System Controller Chassis
32
Front-End Directors
34
Supported Connectors and Protocols
36
Flexible Front-End Director Installation
38
Supported Speeds and Cable Lengths
41
Back-End Director
42
Flexible Back-End Director Installation
42
Drive Chassis
43
Cache Memory
47
Memory Operation
48
Data Protection
48
Cache Capacity
48
Shared Memory
49
Cache Flash Memory
52
Cache Flash Memory Operation
52
Cache Flash Memory Capacity
53
Hardware Architecture
55
System Architecture Overview
57
VSP G1000, VSP G1500, and VSP F1500 RAID Implementation
57
Array Groups and RAID Levels
57
Raid 1
57
Raid 5
59
Raid 6
62
LDEV Striping Across Array Groups
63
Control Unit Images, Logical Volume Images, and Logical Units
65
CU Images
66
Logical Volume Images
66
Logical Units
66
Mainframe Operations
67
Mainframe Compatibility and Functionality
67
Mainframe Operating System Support
67
Mainframe Configuration
67
Open-Systems Operations
68
Open-Systems Compatibility and Functionality
68
Open-Systems Host Platform Support
69
System Configuration
69
Host Modes and Host Mode Options
70
Device Manager - Storage Navigator Program
70
Safety Requirements
73
General Safety Guidelines
74
Work Safety Guidelines
74
Warning about Moving Parts
75
Electrical Safety Guidelines
75
Site Preparation Specifications
77
Responsibilities
78
Customer Responsibilities
78
Hitachi Data Systems Responsibilities
78
Site Preparation Checklist
78
General Site Requirements
81
Equipment Clearances
81
Equipment Weight
81
System Storage Requirements
82
Grounding
82
Power Connection
82
Data Center Requirements
83
Operational Requirements
84
Third-Party Rack Support for VSP G1000, VSP G1500, and VSP F1500 Storage Systems
84
Service Clearance, Floor Cutout, and Floor Load Rating
85
Single-Rack Configuration
85
Two-Rack, Single-Controller Configuration
87
Two-Rack, Dual-Controller Configuration
89
Three-Rack, Single-Controller Configuration
91
Three-Rack, Dual-Controller Configuration
93
Four-Rack Configuration - Two Controllers (Center)
95
Four-Rack Configuration - Two Controllers (Left)
97
Five-Rack Configuration
99
Six-Rack Configuration
101
Seven-Rack Configuration
103
Cable Connection Guidelines
107
Port Configurations
108
Power Connection Diagrams
108
UPS Power Connection
111
Data Connection Diagrams
112
Extended Cable Connections
116
Turning Power on and off to the Storage Systems
125
Power Control Panel
126
System Idle Mode
127
Normal Power On/Off Procedures
128
Power on Procedures
128
Power off Procedures
129
Emergency Power Off/On Procedures
129
Turning off Power to the Storage System During an Emergency
130
Turning on Power to the Storage System after an Emergency Shutdown
130
VSP G1X00 and F1X00 Batteries
131
Battery Backup Operations
132
Cache Backup Batteries
133
Battery Life
133
Storing the System
134
Troubleshooting the Storage System
135
Getting Help
136
Solving Problems
136
Service Information Messages
136
A Storage System Specifications
139
B Mechanical Specifications
145
C Electrical Specifications
147
D Environmental Specifications
151
E Component Power Consumption, Heat Output, and Airflow
153
F Hitachi Universal V2 Rack Power Distribution Units
159
Americas Single-Phase PDU 1P30A-8C13-3C19UL.P
160
Americas Single-Phase PDU 1P30A-15C13-3C19UL.P
160
Americas Three-Phase PDU 3P30A-8C13-3C19UL.P
161
Americas Three-Phase PDU 3P30A-15C13-3C19UL.P
161
Americas Three-Phase PDU 3P30A-24C13-6C19UL.P
162
APAC and EMEA Single-Phase PDU 1P32A-9C13-3C19CE.P
163
APAC and EMEA Single-Phase PDU 1P32A-18C13-3C19CE.P
163
APAC and EMEA Three-Phase PDU 3P16A-9C13-3C19CE.P
164
APAC and EMEA Three-Phase PDU 3P16A-15C13-3C19CE.P
164
APAC and EMEA Three-Phase PDU 3P32A-24C13-6C19CE.P
165
G Regulatory Specifications
167
Regulatory Compliance
168
US FCC Notice
170
Electronic Emissions Testing
170
European Declaration of Conformity
171
Notice of Export Controls
171
China Rohs
171
Hazardous and Toxic Substances
172
Disposal
172
Recycling
172
Electronic Emissions Certificates
172
FIPS 140-2 Consolidated Validation Certificate
176
Glossary
177
Index
189
Advertisement
Hitachi G1000 Hardware Manual (187 pages)
Virtual Storage Platform
Brand:
Hitachi
| Category:
Storage
| Size: 5.28 MB
Table of Contents
Table of Contents
3
Preface
9
Safety and Environmental Information
9
Intended Audience
9
Product Version
9
Release Notes
10
Changes in this Revision
10
Related Documents
10
Document Conventions
10
Conventions for Storage Capacity Values
12
Accessing Product Documentation
13
Getting Help
13
Comments
13
Chapter 1: VSP G1000, VSP G1500, and VSP F1500 Overview
14
System Overview
14
Features
14
High Performance
15
Scalability
16
Flexible Connectivity
17
High Reliability
18
High Flexibility
18
Nondisruptive Service and Upgrades
20
High Temperature Mode
20
Economical and Quiet
22
Chapter 2: Storage System Hardware Overview
23
Storage System Configurations and Model List
23
System Controller Chassis
33
Front-End Directors
36
Supported Connectors and Protocols
38
Flexible Front-End Director Installation
41
Supported Speeds and Cable Lengths
44
Back-End Director
45
Flexible Back-End Director Installation
46
Drive Chassis
46
Cache Memory
51
Memory Operation
53
Data Protection
53
Cache Capacity
53
Shared Memory
54
Cache Flash Memory
58
Cache Flash Memory Operation
58
Cache Flash Memory Capacity
58
Chapter 3: Hardware Architecture
60
System Architecture Overview
60
VSP G1000, VSP G1500, and VSP F1500 RAID Implementation
61
Array Groups and RAID Levels
61
Raid 1
61
Raid 5
63
Raid 6
65
LDEV Striping Across Array Groups
66
Control Unit Images, Logical Volume Images, and Logical Units
68
CU Images
68
Logical Volume Images
69
Logical Units
69
Mainframe Operations
69
Mainframe Compatibility and Functionality
69
Mainframe Operating System Support
70
Mainframe Configuration
70
Open-Systems Operations
71
Open-Systems Compatibility and Functionality
71
Open-Systems Host Platform Support
72
System Configuration
72
Host Modes and Host Mode Options
73
Device Manager - Storage Navigator Program
73
Chapter 4: Site Preparation Specifications
75
Responsibilities
75
Customer Responsibilities
75
Hitachi Vantara Responsibilities
76
Site Preparation Checklist
76
General Site Requirements
79
Equipment Clearances
79
Equipment Weight
79
System Storage Requirements
80
Grounding
80
Power Connection
80
Data Center Requirements
81
Operational Requirements
82
Third-Party Rack Support for VSP G1000, VSP G1500, and VSP F1500 Storage Systems
83
Service Clearance, Floor Cutout, and Floor Load Rating
83
Single-Rack Configuration
83
Two-Rack, Single-Controller Configuration
85
Two-Rack, Dual-Controller Configuration
87
Three-Rack, Single-Controller Configuration
89
Three-Rack, Dual-Controller Configuration
91
Four-Rack Configuration - Two Controllers (Center)
93
Four-Rack Configuration - Two Controllers (Left)
95
Five-Rack Configuration
97
Six-Rack Configuration
99
Seven-Rack Configuration
101
Chapter 5: Cable Connection Guidelines
104
Port Configurations
104
Power Connection Diagrams
105
UPS Power Connection
107
Data Connection Diagrams
108
Extended Cable Connections
112
Chapter 6: Turning Power on and off to the Storage Systems
119
Power Control Panel
119
System Idle Mode
121
Normal Power On/Off Procedures
121
Power on Procedures
122
Power off Procedures
122
Emergency Power Off/On Procedures
123
Turning off Power to the Storage System During an Emergency
123
Turning on Power to the Storage System after an Emergency Shutdown
124
Chapter 7: VSP G1X00 and F1X00 Batteries
125
Battery Backup Operations
125
Cache Backup Batteries
126
Battery Life
127
Storing the System
127
Chapter 8: Troubleshooting the Storage System
128
Getting Help
128
Solving Problems
128
Service Information Messages
129
Appendix A: Storage System Specifications
131
Appendix B: Mechanical Specifications
139
Appendix C: Electrical Specifications
140
Appendix D: Environmental Specifications
143
Appendix E: Component Power Consumption, Heat Output, and Airflow
146
Airflow
146
Appendix F: Power Distribution Units for Hitachi Universal V2 Rack
153
Americas Single-Phase PDU 1P30A-8C13-3C19UL.P
153
Americas Single-Phase PDU 1P30A-15C13-3C19UL.P
154
Americas Three-Phase PDU 3P30A-8C13-3C19UL.P
154
Americas Three-Phase PDU 3P30A-15C13-3C19UL.P
155
Americas Three-Phase PDU 3P30A-24C13-6C19UL.P
156
APAC and EMEA Single-Phase PDU 1P32A-9C13-3C19CE.P
157
APAC and EMEA Single-Phase PDU 1P32A-18C13-3C19CE.P
158
APAC and EMEA Three-Phase PDU 3P16A-9C13-3C19CE.P
159
APAC and EMEA Three-Phase PDU 3P16A-15C13-3C19CE.P
160
APAC and EMEA Three-Phase PDU 3P32A-24C13-6C19CE.P
161
Appendix G: Safety Requirements
163
General Safety Guidelines
163
Work Safety Guidelines
164
Warning about Moving Parts
164
Electrical Safety Guidelines
165
Appendix H: Regulatory Specifications
166
Regulatory Compliance
166
US FCC Notice
169
Electronic Emissions Testing
169
European Declaration of Conformity
169
Notice of Export Controls
170
China Rohs
170
Hazardous and Toxic Substances
170
Disposal
171
Recycling
171
Electronic Emissions Certificates
171
FIPS 140-2 Consolidated Validation Certificate
175
Glossary
176
Index
184
Hitachi G1000 User Manual (88 pages)
Virtual Storage Platform, Encryption License Key
Brand:
Hitachi
| Category:
Storage
| Size: 1.14 MB
Table of Contents
Table of Contents
3
Preface
7
Intended Audience
8
Product Version
8
Document Revision Level
8
Changes in this Revision
8
Referenced Documents
8
Document Conventions
9
Accessing Product Documentation
10
Getting Help
10
Comments
10
1 Encryption License Key Overview
11
Encryption License Key Benefits
12
Encryption License Key Support Specifications
12
When Are Data Encryption License Keys Needed
13
Primary and Secondary Data Encryption License Keys
13
KMIP Key Management Server Support
14
Audit Logging of Encryption Events
14
Interoperability Requirements and Considerations
15
Workflow for Enabling Data Encryption
15
Workflow for Encrypting Existing Data
15
Workflow for Disabling Encryption
16
Workflow for Changing the Encryption License Key
16
2 Encryption License Key Installation
17
Workflow for Encryption License Key Installation
18
System Requirements
18
Enabling the Encryption License Key Feature
18
Disabling the Encryption License Key Feature
19
3 Key Management Server Connections
21
Key Management Server Requirements
22
Root and Client Certificates
22
Root Certificate on the Key Management Server
22
Client Certificate Password
22
Workflow for Preparing the Client Certificate
23
Converting the Client Certificate to the PKCS#12 Format
23
Uploading the Root and Client Certificate
23
Workflow for Edit Encryption Environmental Settings
24
Configuring the Connection Settings to the Key Management Server
25
Settings in the Edit Encryption Environmental Settings Window
26
4 Managing Data Encryption License Keys
29
Workflow for Creating Data Encryption License Keys
30
Creating Data Encryption License Keys
30
Workflow for Backing up Secondary Data Encryption License Keys
31
Backing up Keys as a File
32
Backing up Keys to a Key Management Server
32
Opening the Backup Keys to Server Window Using the Encryption Window
33
Opening the Backup Keys to Server Window Using the View Backup Keys on Server Window
34
Editing the Password Policy
34
Workflow for Enabling Data Encryption on Parity Groups
35
Enabling Data Encryption at the Parity Group-Level
35
Workflow for Disabling Data Encryption at the Parity-Group Level
36
Disabling Data Encryption at the Parity-Group Level
37
Encryption Formatting at the Parity-Group Level
38
Workflow for Restoring Data Encryption License Keys
38
Restoring Keys from a File
39
Restoring Keys from a Key Management Server
40
Workflow for Deleting Data Encryption License Keys
40
Deleting Data Encryption License Keys
41
Deleting Backup Data Encryption License Keys from the Server
42
Viewing Encryption Keys Backed up on the Key Management Server
43
Exporting Encryption License Key Table Information
43
Rekeying Key Encryption Keys
44
Rekeying Certificate Encryption Keys
44
Retrying Key Encryption Key Acquisition
45
Initialize the Connection Settings to the Key Management Server
46
5 Troubleshooting
47
Troubleshooting for Encryption License Key
48
Contacting the Hitachi Data Systems Support Center
49
A Encryption License Key GUI Reference
51
Encryption Keys Window
51
Edit Encryption Environmental Settings Wizard
51
Edit Encryption Environmental Settings Window
55
Edit Encryption Environmental Settings Confirmation Window
59
Create Keys Wizard
60
Create Keys Window
61
Create Keys Confirmation Window
61
Edit Password Policy (Backup Encryption Keys) Wizard
62
Edit Password Policy (Backup Encryption Keys) Window
62
Edit Password Policy (Backup Encryption Keys) Confirmation Window
63
Backup Keys to File Wizard
64
Backup Keys to File Window
65
Backup Keys to File Confirmation Window
66
Backup Keys to Server Wizard
66
Backup Keys to Server Window
67
Backup Keys to Server Confirmation Window
67
Restore Keys from File Wizard
68
Restore Keys from File Window
68
Restore Keys Confirmation Window
69
Restore Keys from Server Wizard
69
Restore Keys from Server Window
70
Restore Keys from Server Confirmation Window
70
Delete Keys Wizard
71
Delete Keys Window
71
Delete Keys Confirmation Window
72
Delete Backup Keys on Server Window
72
View Backup Keys on Server Window
73
Edit Encryption Wizard
74
Edit Encryption Window
75
Edit Encryption Confirmation Window
77
Rekey Certificate Encryption Keys Window
79
Rekey Key Encryption Key Window
79
Retry Key Encryption Key Acquisition Window
80
Glossary
81
Index
85
Hitachi G1000 User Manual (40 pages)
Virtual Storage Platform, Volume Shredder
Brand:
Hitachi
| Category:
Storage
| Size: 0.48 MB
Table of Contents
Table of Contents
3
Preface
5
Intended Audience
6
Product Version
6
Document Revision Level
6
Changes in this Revision
6
Referenced Documents
6
Document Conventions
6
Convention for Storage Capacity Values
8
Accessing Product Documentation
8
Getting Help
8
Comments
8
1 Overview of Hitachi Volume Shredder
9
Data Security Practices and Volume Shredder
10
Supported Volume Types
10
Volume Shredder Operations
10
Shredding Times
12
2 Volume Shredder Operations
15
Workflow for Shredding
16
Blocking a Volume
16
Blocking Volumes in a Parity Group
17
Calculating the Number of Overwrite Passes for Flash Drives
18
Example of Shredding Data on Flash Drives
18
Calculating the Number of Overwrite Passes for Fmds
19
Example of Shredding Data on Fmds
20
Defining Shredding Conditions
20
Shredding a Volume
21
Shredding Volumes in Parity Groups
22
Viewing Shredding Status with the Tasks Window
23
Viewing Shredding Status with the Logical Devices Window
24
Stopping a Shredding Operation
24
Viewing Shredding Results with the Tasks Window
25
Viewing Shredding Results in the Compressed Files
26
Volume Shredder GUI Reference
29
Shred Ldevs Wizard
30
Shred Ldevs Window
30
Shred Ldevs Wizard Confirm Window
31
Edit Shredding Data Pattern Window
33
Related Topics
35
Advertisement
Related Products
Hitachi Virtual Storage Platform G130
Hitachi G1500
Hitachi Virtual Storage Platform G600
Hitachi Virtual Storage Platform G800
Hitachi G900
Hitachi Virtual Storage Platform G350
Hitachi Virtual Storage Platform G370
Hitachi SVP G 00 Series
Hitachi G/F900
Hitachi G/F800
Hitachi Categories
Projector
Air Conditioner
Drill
Power Tool
TV
More Hitachi Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL