Operation, Display and Application Examples
3.7.2
Frequency Setting by the Auxiliary Frequency Source
The frequency setting by the auxiliary frequency source is the same as the frequency setting
by the main frequency source. You can set the auxiliary frequency source in P0-04.
Figure 3-16 Frequency set by the auxiliary frequency source
On extension
board
PD.00~PD.05
Host computer
Communication
configuration
The relationship between the target running frequency and the main frequency source and
auxiliary frequency source is set in P0-07, as follows:
Main frequency source X: The main frequency source is directly used to set the target
running frequency.
Auxiliary frequency source Y: The auxiliary frequency source is directly used to set the
target running frequency.
X and Y operation: There are four operation methods, namely, X+Y, X-Y, maximum of X
and Y, and minimum of X and Y.
Frequency switchover: A DI terminal is used to switch over between the preceding three
frequency setting channels.
The following figure shows how to set the relationship in P0-07, in which the bold line indicates
the default setting.
Retentive at
power failure
Each frequency
Group PC
Simple PLC
Group PA
H1000 register
Digital setting
Analog
Analog
Analog
P0-04
Main
Pulse setting
frequency
source Y
Multi-speed
selection
Communication
setting