A6-06
Corresponding setting of AI curve 4
A6-07
A6-08
Corresponding setting of AI curve 5
A6-09
A6-10
Corresponding setting of AI curve 5
A6-11
A6-12
Corresponding setting of AI curve 5
A6-13
A6-14
Corresponding setting of AI curve 5
A6-15
The function of curve 4 and curve 5 is similar to that curve 1 to curve 3, but curve 1 to curve 3
are lines, and curve 4 and curve 5 are 4-point curves, implementing more flexible corresponding
relationship. The schematic diagram of curve 4 and curve 5 is shown in the following figure.
AI curve 4 maximum input
Setting Range
maximum input
Setting Range
AI curve 5 minimum input
Setting Range
minimum input
Setting Range
AI curve 5 inflexion 1 input
Setting Range
inflexion 1 input
Setting Range
AI curve 5 inflexion 1 input
Setting Range
inflexion 1 input
Setting Range
AI curve 5 maximum input
Setting Range
maximum input
Setting Range
Default
Default
Default
Default
Default
Default
Default
Default
Default
Default
173
Description of Function Codes
10.00 V
A6-06 to 10.00 V
100.0%
-100.0%–100.0%
0.00 V
-10.00 V to A6-10
0.0%
-100.0%–100.0%
3.00 V
A6-08 to A6-12
30.0%
-100.0%–100.0%
6.00 V
A6-10 to A6-14
60.0%
-100.0%–100.0%
10.00 V
A6-14 to 10.00 V
100.0%
-100.0%–100.0%