Advanced menus The Advanced menu can be used to configure the following protections
20 | © 2019 ABB | 1SDH001316R1002 - ECN000086501 - Rev. A
Name
Parameters
MCR
Description and list in manual 1SDH001330R1001
2I
Description and list in manual 1SDH001330R1001
IU
Description and list in manual 1SDH001330R1001
UV
Description and list in manual 1SDH001330R1001
(2)
OV
Description and list in manual 1SDH001330R1001
(2)
UV2
Description and list in manual 1SDH001330R1001
(2)
OV2
Description and list in manual 1SDH001330R1001
(2)
VU
Description and list in manual 1SDH001330R1001
(2)
S(V)
Description and list in manual 1SDH001330R1001
(2)
S2(V)
Description and list in manual 1SDH001330R1001
(2)
RV
Description and list in manual 1SDH001330R1001
(2)
UF
Description and list in manual 1SDH001330R1001
(2)
OF
Description and list in manual 1SDH001330R1001
(2)
UF2
Description and list in manual 1SDH001330R1001
(2)
OF2
Description and list in manual 1SDH001330R1001
(2)
RP
Description and list in manual 1SDH001330R1001
(2)
D
Description and list in manual 1SDH001330R1001
(2)
RQ
Description and list in manual 1SDH001330R1001
(2)
OQ
Description and list in manual 1SDH001330R1001
(2)
UP
Description and list in manual 1SDH001330R1001
(2)
OP
Description and list in manual 1SDH001330R1001
(2)
ROCOF
Description and list in manual 1SDH001330R1001
(2)
V DIR, VINV
Description and list in manual 1SDH001330R1001
(2)
59 S1
Description and list in manual 1SDH001330R1001
(2)
Warnings
VS Warning, FS Warning, FW1 Warning
Threshold 1 I1, Threshold 2 I1, Threshold Iw1, Threshold Iw2,
Signallings
Phase Sequence
Functions
External Trip, Trip Reset, Switch On SET B
Synchrocheck
Description and list in manual 1SDH001330R1001
RC
Description and list in manual 1SDH001330R1001
Adaptive Protections
(1)
if the
where the set can be selected (Set A / Set B) will be available before the list of protections The only menu
Advanced
always present via
(2)
available if provided for by Trip unit model or if the relative SW package has been activated, where possible
(page 6)
(3)
CosØ available if provided for by Trip unit model or if the
SET B
Adaptive Protections
(4)
available when
Ekip Synchrocheck
(5)
available when
Rating Plug
(6)
available when
previously activated in Settings menu
, CosØ
(2)
(3)
Dual set
package is available and
Functions
is
Power Protections
package is present
is present
Rc
type
is installed in unit and when presence of
ABB | SACE Emax 2
:
(1)
SW package
Standard
Protections
Voltage protections
Voltage Advanced
protections
Frequency
protections
Power protections
ROCOF protections
Interface
protections (IPS)
Standard
Protections
(4)
(5)
(6)
has been activated, an intermediate menu
package has been activated
Rc sensor Rc
Interface and menus | 4 - Menu
has been