Figure 48
1. Positive (+) battery post
2. Negative (–) battery post
Installing the Battery
1.
Position the battery in the tray with the terminal
posts opposite from the hydraulic tank
47).
2.
Install the positive (red) battery cable to the
positive (+) battery terminal.
3.
Install the negative (black) battery cable and
ground wire to the negative (-) battery terminal.
4.
Secure the cables with 2 bolts, 2 washers, and
2 locknuts
(Figure
5.
Slide the red terminal boot onto the positive
(red) battery post.
6.
Install the clamp and secure it with the wing nuts
and J-hooks
(Figure
3. Red (+) charger lead
4. Black (–) charger lead
(Figure
47).
47).
Adjusting the Safety
Switches
Adjust all safety switches so that the plunger extends
4.8 mm to 6.4 mm (3/16 inch to 1/4 inch) from the
switch body when the plunger is compressed
49).
g000960
1. 4.8 to 6.4 mm (3/16 to 1/4 inch)
Servicing the Fuses
The electrical system is protected by fuses. It requires
no maintenance; however, if a fuse blows check the
component/circuit for a malfunction or short.
1.
The fuses are located on right side behind the
seat.
2.
To replace the fuses, pull out on the fuse to
remove it.
3.
Install a new fuse.
42
Figure 49
(Figure
g006849