F54 - Short Circuit, Roast Probe; F55 - Safety Cutoff; F60 - Temperature Of Power Electronic Too High; Incorrect Language Was Set - Miele H 408 BM Series Technical Information

Speed oven
Table of Contents

Advertisement

H 408x BM
Cause:
Power electronic (1N1) defective.
Remedy:
Replace power electronic.
3.5
F54 – Short Circuit, Roast Probe
Cause:
Temperature sensor 2R30 short-circuited.
Remedy:
1. Check connectors.
2. Replace connectors as necessary.
3. Check the roast probe temperature sensor in the service mode; see
Section 040-4.3.
4. Replace the roast probe temperature sensor as necessary.
3.6
F55 – Safety Cutoff
Symptom:
After 6 hours or 12 hours, depending on operating mode, the appliance
switches off automatically.
Cause:
The appliance was not switched off.
Remedy:
No action necessary; the appliance is in working order.
3.7
F60 – Temperature of Power Electronic Too High
Symptom:
The temperature of the power electronic (1N1) is too high.
Cause:
Insufficient ducting.
Remedy:
1. Check the ducting; refer to Section 012-2.1.
2. Check the cooling fan connectors; replace as necessary.
3. Check the cooling fan in service mode; see Section 040-4.3.
4. Replace the cooling fan as necessary.
3.8

Incorrect Language Was Set

Cause:
Different languages can be programmed.
Remedy:
Use the
3.9

Time Display in 24-Hour Format/12-Hour Format

Cause:
The time format can be programmed.
Remedy:
See Section 040-4.1.
icon as a guide to program the desired language.
67
Technical Information

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H 4080 bmH 4082 bH 4084 bH 4086 bH 4088 b

Table of Contents