Rear Air Duct With Cooling Fan (M2/1) Removal; Figure 012-4: Front Air Duct Removal - Miele H 408 BM Series Technical Information

Speed oven
Table of Contents

Advertisement

Technical Information

Figure 012-4: Front Air Duct Removal

Note:
When installing the front air duct, make sure that the air baffle below it can
move freely.
Danger!
After installation is completed, as a matter of standard practice, check the
oven for a tight seal with a microwave leak detector, paying particular attention
to the door and the housing edges.
4.2

Rear Air Duct with Cooling Fan (M2/1) Removal

1. Remove the appliance from its cabinet; see Section 011-4.3.
2. Remove the screws securing the appliance lid. Remove the lid.
Danger!
Before performing any service or repair work, discharge the high-voltage
capacitor. See Section A-2.
3. Remove the EV790 electronic module (3N1) (Figure 012-5, Item 1).
4. Remove the safety relay.
5. Disconnect the magnetron connections (Figure 012-5, Item 2).
6. Disconnect the high-voltage transformer connections (Figure 012-5, Item 3).
7. Disconnect the cooling fan connections (Figure 012-5, Item 4).
8. Remove the screws securing the rear air duct (Figure 012-5, Item 5).
9. Remove the rear air duct with cooling fan.