C Using PROFINET Configurator Express

Creating controller network configuration file using PROFINET Configurator Express
Description
The following example is performed using PROFINET Configurator Express.
This example demonstrates how to create a PROFINET configuration file for one
device, a Siemens ET200S with 5 DO 2-bit modules and 1 DI 2-bit module.
1
2
3
4
5
6
Application manual - PROFINET Controller/Device
3HAC050969-001 Revision: G
Action
Start PROFINET-IO Configurator Express.
In PROFINET-IO Configurator Express, click File and select New to create a new
empty project.
Click File and select Save to save the new project. Use the name "TestProject".
In the Bus Structure window, make sure that the "TestProject" node is selected.
In the Device Details window, set the PROFINET IP range for this project by setting
the following parameters:
Last IP Address: 192.168.5.254
First IP Address: 192.168.5.2
Subnetmask: 255.255.255.0
en1100000063
In the Device Catalog window, expand the nodes Phoenix Contact Software GmbH,
Generic PN and PLC.
Select the PLC version that corresponds to the current version of the Phoenix
Contact Software. Currently, it is 3.9 version.