6.5 Type PROFINET Internal Device
6.5.1 Input Size
Parent
Input Size belongs to the type PROFINET Internal Device, in the topic I/O System.
Cfg name
InputSize
Description
The parameter Input Size is used to configure the input slot configuration of the
PROFINET internal device.
Usage
It will configure the input slot size for the PROFINET internal device. This size must
match the connecting PLC's or other PROFINET controller's defined output slot
size. For more information, see
Prerequisites
The option PROFINET Controller/Device or PROFINET Device must be installed.
Default value
The default value is 64 bytes (512 signal bits).
Allowed values
8, 16, 32, 64, 128 or 256 bytes (64, 128, 512, 1024 or 2048 signal bits).
Application manual - PROFINET Controller/Device
3HAC050969-001 Revision: G
Input and output size on page
© Copyright 2015-2018 ABB. All rights reserved.