Table 2
cables you are using with terminal devices or other appropriate equipment.
Table 2 Pin Assignments for DB9 and DB25 Interface Cables
Console or serial
pin and assignment
Shield (FG)
2 (RXD)
3 (TXD)
4 (DTR)
5 (SG)
6 (DSR)
7 (RTS)
8 (CTS)
System Status LEDs
You can monitor the basic operation of Check Point IP150 appliances by checking their status
LEDs. The system status LEDs are located on the front panel of the appliance, as
shows.
Figure 5 Appliance Status LEDs
14
shows how to match pins at the console connector with output pins on DB9 or DB25
DB9 cable output pin and
assignment
Shield (FG)
3 (TXD)
2 (RXD)
6 (DSR)
5 (SG)
4 (DTR)
8 (CTS)
7 (RTS)
POWER
STATUS
FAULT
Power
Status
Fault
DB25 cable output pin and
assignment
1 (FG)
2 (TXD)
3 (RXD)
6 (DSR)
7 (SG)
20 (DTR)
5 (CTS)
4 (RTS)
AUX
CON SOLE
1
2
Check Point IP150 Security Platform Installation Guide
Figure 5
IP150
3
4