NEC UNIVERGE SV8300 Pc Programming Manual page 232

Hide thumbs Also See for UNIVERGE SV8300:
Table of Contents

Advertisement

(3)
Cannot obtain an Activation Code from the Software License Authentication Center
No.
1
An attempt was made to use license
data already authenticated to create a
PBX creation file on another SV8300
and to register it with the Software
License Authentication Center
(illegal copying).
(4)
Cannot register a temporary Activation Code or Activation Code
No.
1
Invalid temporary
Activation Code or
Activation Code.
2
Unstable communica-
tion between PCPro
and the SV8300.
(5)
Error type 017 is set to point to an MJ alarm in the PCPro fault display
No.
1
Invalid Activation
Code.
2
The system was initialized after registering new
license data while a former Activation Code had
already been registered on it.
3
Thirty days have passed since you started running the
system without registering an Activation Code fol-
lowing the registration of a temporary Activation
Code (4320).
Cause
Cause
The Activation Code for
another SV8300 is used.
The SV8300 was in a con-
gested state, unable to
receive a maintenance
command.
Noise present on the com-
munications line
Cause
The Activation Code for
another SV8300 is used.
Remedial action
Create a PBX creation file using license data that is
not yet authenticated and register it with the Soft-
ware License Authentication Center.
Enter a valid Activation Code.
Wait for a while and retry the communi-
cation session.
Connect PCPro and the SV8300 directly
with RS CONSOLE CA-A.
Enter a valid Activation Code.
Access the Software License Authen-
tication Center to obtain an Activation
Code and set it on the SV8300.
Access the Software License Authen-
tication Center to obtain an Activation
Code and set it on the SV8300.
C-20
Appendix C Troubleshooting
Remedial action
Remedial action
NWA-033628-001 Rev.1.0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents