4 BBU3900 Cables
Figure 4-5 Appearance of power cable(DC OMB)
(1) 3V3 power connector
4.5 E1/T1 Cable
The E1/T1 cable connects the BBU to the external transmission device and transmits baseband
signals.
Exterior
The E1/T1 cables are classified into two types: 75-ohm E1 coaxial cable and 120-ohm E1 twisted
pair cable.
One end of the E1/T1 cable is a DB26 male connector. The connector at the other end of the
cable should be made on site according to site requirements.
Figure 4-6 E1/T1 cable
(1) DB26 male connector
Table 4-4
Table 4-4 Connectors of the 75-ohm E1 coaxial cable
Cable
75-ohm E1 coaxial cable
4-8
describes the connectors of the 75-ohm E1 coaxial cable.
One End
DB26 male connector
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Hardware Description
(2) OT terminal
Figure 4-6
shows an E1/T1 cable.
The other End
L9 male connector
L9 female connector
SMB female connector
Issue 11 (2010-11-10)