Siemens SINUMERIK 840D Series Diagnostics Manual page 55

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

11.02
4342
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
4343
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
4345
Parameters:
Definitions:
Reactions:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Channel %1 invalid machine data for general 5-axis transformation error no. %2
%1 = Channel number
%2 = Error type
The machine data which describe the axis directions and the base orientation for the gen-
eral 5-axis transformation are invalid. The error parameter displayed specifies the cause
of the alarm:
• 1: The first axis (TRAFO5_AXIS1_*) is not defined (all three entries of the vector are 0)
• 2: The second axis (TRAFO5_AXIS2_*) is not defined (all three entries of the vector are
0)
• 3: The base orientation (RAFO5_BASE_ORIEN_*) is not defined (all three entries of
the vector are 0)
• 4: The first and second axis are (virtually) parallel
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
- NC Stop on alarm at block end.
Set valid machine data.
Clear alarm with the RESET key. Restart part program
Channel %1 attempt made to change the machine data of an active transformation.
%1 = Channel number
An attempt was made to change the machine data of an active transformation and to acti-
vate the machine data with RESET or NEWCONFIG.
- Alarm display.
- Interface signals are set.
- Interpreter stop
- NC Stop on alarm at block end.
Set valid machine data.
Clear alarm with the RESET key. Restart part program
Channel %1 invalid configuration in chained transformation no. %2
%1 = Channel number
%2 = Transformation number
A chained transformation is incorrectly configured (machine data
$MC_TRACON_CHAIN_1 or $MC_TRACON_CHAIN_2). The following causes for the
error are possible:
• The list of transformations to be chained starts with a 0 (at least one entry not equal to
zero is required).
• The list of transformations to be chained contains the number of a transformation which
does not exist.
• The number of a transformation in the list is greater than or equal to the number of the
chained transformation. Example: The cascaded transformation is the fourth transfor-
mation in the system, i.e. $MC_TRAFO_TYPE_4 = 8192. In this case, only values 1, 2
or 3 may be entered in the associated list (e.g. $MC_TRACON_CHAIN_1[...]).
• The chaining setting is invalid. The following restrictions currently apply. A maximum of
two transformations can be chained. The first transformation must be an orientation
transformation, transmit, peripheral curve transformation or inclined axis. The second
transformation must be the inclined axis transformation.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
- NC Stop on alarm at block end.
1 Alarms
1-55

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di seriesSinumerik 810d seriesSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840de ... Show all

Table of Contents