11.02
75270
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
75275
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
75451
Definitions:
Reactions:
Remedy:
Program Continuation:
75452
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
75500
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Channel %1 tool parameters incorrect
%1 = Channel number
The tool parameters are not the same as the settings for the handling transformation
package (checked in interpolation).
- NC Stop on alarm.
- NC Start disable in this channel.
Correct tool parameters.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 working area error
%1 = Channel number
%2 = Block number, label
The programmed point is not within the working range of the kinematic (checked during
main run).
- Interpreter stop
- NC Start disable in this channel.
Correct position.
Clear alarm with the RESET key. Restart part program
Error with definition of setpoint switchover
Exchange axis number and machine axis number are identical, gaps have been defined,
or the machine axis number is the machine axis number of an inactive machine axis of the
system.
- The NC switches to follow-up mode.
Enter another axis number for the setpoint exchange in MD 63750.
Switch control OFF - ON.
Axis %1 setpoint switchover not possible in the current state
%1 = Axis name
The axes included in the setpoint exchange group are not all stationary (DB3x.DBB61.4)
No ModeGroupReady signal
One of the two axes in the setpoint exchange group is already configured in another
active setpoint exchange. Enter a valid value in drive MD 63750:
CTRLOUT_CHANGE_TAB[0.2] for the setpoint exchange to be activated equals zero. A
new exchange has been requested via PLC before the function has been returned to its
initial state.
- Alarm display.
Enter another axis number for the setpoint exchange in MD 63750.
Clear alarm with the RESET key. Restart part program
Channel %1 wrong configuration
%1 = Channel number
There are two causes of this alarm:
- No geometry axis has been defined
- The option "Software cam" is set.
- Alarm display.
Modify configuration.
Clear alarm with the RESET key. Restart part program