11.02
Reactions:
Remedy:
Program Continuation:
18003
Parameters:
Definitions:
Reactions:
Remedy:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
9: Protection zone to be activated is not defined.
10: Error in internal structure of the protection zones.
11: Other errors not specified further.
12: The number of protection zones simultaneously active exceeds the maximum number
(channel-specific machine data).
13,14: Contour element for protection zones cannot be created.
15,16: No more memory space for the protection zones.
17: No more memory space for the contour elements.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Please inform the authorized personnel/service department.
1. Reduce the number of simultaneously active protection zones (MD).
2. Modify part program:
• Delete other protection zones.
• Preprocessing stop.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 NCK protection zone %3 cannot be activated.Error code %4
%1 = Channel number
%2 = Block number, label
%3 = Number of channel-specific protection zone
%4 = Error specification
An error has occurred on activating the protection zone. The error number gives the spe-
cific reason for the alarm.
The following meanings apply:
1: Incomplete or conflicting contour definition.
2: Contour encompasses more than one surface area.
3: Tool-related protection zone is not convex.
4: If both boundaries are active in the 3rd dimension of the protection zone and both limits
have the same value.
5: The number of the protection zone does not exist (negative number, zero or greater
than the maximum number of protection zones).
6: Protection zone definition consists of more than 10 contour elements.
7: Tool-related protection zone is defined as inside protection zone.
8: Incorrect parameter used.
9: Protection zone to be activated is not defined.
10: Error in internal structure of the protection zones.
11: Other errors not specified further.
12: The number of protection zones simultaneously active exceeds the maximum number
(channel-specific machine data).
13,14: Contour element for protection zones cannot be created.
15,16: No more memory space for the protection zones.
17: No more memory space for the contour elements.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Please inform the authorized personnel/service department.
1. Reduce the number of simultaneously active protection zones (MD).
2. Modify part program: