11.02
Reactions:
Remedy:
Program Continuation:
14415
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14420
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14500
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14510
Parameters:
Definitions:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Modify part program or correction block.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 tangent control: changeover geometry/channel axis not
allowed
%1 = Channel number
%2 = Block number, label
An assignment change of the geometry axes to channel axes is not permitted with active
tangential control.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Change part program and delete active tangential control with TANGDEL.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 index axis %3 frame not allowed
%1 = Channel number
%2 = Block number, label
%3 = Axis
The axis is to be traversed as an indexing axis, but a frame is active. This is not allowed
by machine data FRAME_OR_CORRPOS_NOTALLOWED.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Please inform the authorized personnel/service department. Modify part program.
Change machine data CORR_FOR_AXIS_NOT_ALLOWED.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 illegal DEF or PROC instruction in the part program
%1 = Channel number
%2 = Block number, label
NC part programs with high-level language elements are divided into a preceding defini-
tion part followed by a program part. The transition is not marked specifically; a definition
statement is not allowed to follow the first program command.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Put definition and PROFC statements at the beginning of the program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 PROC instruction missing on subroutine call
%1 = Channel number
%2 = Block number, label
In subroutine calls with parameter transfer ("call-by-value" or "call-by-reference") the
called subroutine must begin with a PROC statement.
1 Alarms