1 Alarms
Definitions:
Reactions:
Remedy:
Program Continuation:
12090
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12100
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-126
At the text position shown, the grammar in the block is incorrect. The precise reason for
this error cannot be specified in more detail because there are too many possibilities.
Example 1:
N10 IF GOTOF ... ; the condition for the jump is missing!
Example 2:
N10 DEF INT VARI=5
N11 X VARI ; the operation is missing for the X and VARI variables
- Alarm display.
- Interface signals are set.
- Correction block
Press the NC Stop key and select the function "Correction block" with the soft key PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block.
Analyze the block and correct it in accordance with the syntax rules given in the Program-
ming Guide.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 unexpected parameter %3
%1 = Channel number
%2 = Block number, label
%3 = Disallowed parameters in the text
The programmed function has been predefined; no parameters are allowed in its call. The
first unexpected parameter is displayed.
Example: On calling the predefined subroutine TRAFOF (switching off a transformation)
parameters have been transferred (one or more).
- Correction block
- Interface signals are set.
- Alarm display.
Press the NC Stop key and select the function "Correction block" with the soft key PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block.
Program function without parameter transfer.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 number of passes %3 not permissible
%1 = Channel number
%2 = Block number, label
%3 = Number of passes
The subroutines called with MCALL are modal, i.e. after each block with positional infor-
mation a routine run is automatically performed once. For this reason, programming of the
number of passes under address P is not allowed.
The modal call is effective until another MCALL is programmed, either with a new subrou-
tine name or without (delete function).
- Alarm display.
- Interface signals are set.
- Correction block
Press the NC Stop key and select the function "Correction block" with the soft key PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block.
Program the subroutine call MCALL without number of passes.
Clear alarm with NC START or RESET key and continue the program.