Siemens SINUMERIK 840D Series Diagnostics Manual page 217

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

11.02
Reactions:
Remedy:
Program Continuation:
15800
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
15810
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
15900
Parameters:
Definitions:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Alarm reactions of Siemens standard cycles:
Nos. 61,000 -61,999: Interpreter stop; delete with Reset
Nos. 62 000 - 62 999: Compensation block; delete with NC Start
- Alarm display.
- Interface signals are set.
- Interpreter stop
- NC Start disable in this channel.
Program alarm number in the SETAL instruction in the correct range.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 wrong starting conditions for CONTPRON/CONTDCON
%1 = Channel number
%2 = Block number, label
There is an error in the start conditions for CONTPRON/CONDCON:
• G40 not active
• SPLINE or POLY active
- Alarm display.
- Interface signals are set.
- Interpreter stop
- NC Start disable in this channel.
Modify part program.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 wrong array dimension for CONTPRON/CONTDCON
%1 = Channel number
%2 = Block number, label
The number of columns for the array created for CONTPRON/CONTDCON does not con-
form to the current programming guide.
- Alarm display.
- Interface signals are set.
- Interpreter stop
- NC Start disable in this channel.
Modify part program.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 touch probe not allowed
%1 = Channel number
%2 = Block number, label
Measure with deletion of distance-to-go
In the part program, an illegal probe has been programmed with the command MEAS
(measure with deletion of distance-to-go). The probe numbers
0 ... no probe
1 ... probe 1
2 ... probe 2
are allowed, whether the probe is actually connected or not.
Example:
N10 MEAS=2 G01 X100 Y200 Z300 F1000
Probe 2 with deletion of distance-to-go
1 Alarms
1-217