1 Alarms
Program Continuation:
14610
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14650
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14660
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-192
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 compensation block not possible
%1 = Channel number
%2 = Block number, label
An alarm was output which could be eliminated basically via program correction. Since
the error occurred in a program which is processed from external, a compensation block/
program correction is not possible.
- Alarm display.
- Interface signals are set.
- Interpreter stop
- NC Start disable in this channel.
• Abort program with reset.
• Correct program on MMC or PC.
• Restart reloading (possibly with block search and interrupt location).
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 SETINT instruction with invalid ASUP input
%1 = Channel number
%2 = Block number, label
Asynchronous subroutines are subroutines that are executed following a hardware input
(interrupt routine started by a rapid NCK input).
The NCK input number must lie between 1 and 8. It is assigned a priority from 0 to 128 (1
is the highest priority) in the SETINT instruction with the keyword PRIO = ... .
Example:
If NCK input 5 changes to "1" the subroutine LIFT_Z should be started with the highest
priority.
N100 SETINT (5) PRIO = 1 LIFT_Z
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Program the NCK input of the SETINT statement with a value of not less than 1 or greater
than 8.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 SETINT instruction with invalid priority
%1 = Channel number
%2 = Block number, label
The NCK input number must lie between 1 and 8. It is assigned a priority from 0 to 128 (1
is the highest priority) in the SETINT instruction with the keyword PRIO = ... .
Example:
If NCK input 5 changes to "1" the subroutine LIFT_Z should be started with the highest
priority.
N100 SETINT (5) PRIO = 1 LIFT_Z
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Program the priority of the NCK input with a value of not less than 1 or greater than 128.
Clear alarm with NC START or RESET key and continue the program.
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
 Siemens AG, 2002. All rights reserved