ZoneScape 1-A module documentation
.
6. Connect the output of the 15VAC transformer to the 15VAC input of the
ZoneScape using three (3) wires (Com #1, 15V and Ground).
CAUTION: WIRING MUST COMPLY WITH THE NATIONAL ELECTRICAL AND LOCAL
CODES.
7. Connect the outputs from the ZoneScape (ZONES 1 - 4) to the appropriate lighting
fixtures.
8. Plug the15VAC transformer into 120VAC electrical outlet and turn the power
switch to the ON position.
Below is an example wiring diagram showing the ZoneScape module terminals. On
the left the first terminal pair is the 15V power input.

ZoneScape Wiring Diagram

ZoneScape has one low voltage AC power input (refer to the module specifications
sheet for absolute maximum ratings) , for connecting to a standard low voltage
garden lighting transformer. Every unit also have four outputs which provide power
for every single relay Zone . The outputs are named Zone "1", "2" , "3" and "4" .
The ZoneScape input voltage as per the specifications sheet is 15,5V AC . Maximum
load per zone is 8A @ 15.5V . The ZoneScape input voltage shall not exceed 24V AC
max. ZoneScape is equipped with a terminal bar for connecting the transformer
input and terminals for zone outputs. The transformer input shall be connected to
the terminals labelled AC / 15V IN . The outputs for the four zone relays shall be
connected to terminals ZONE 1 / OUT , ZONE 2 / OUT, ZONE 3 / OUT and ZONE 4 /
OUT .