Configuring the system
2.3 Configuration file "basesys.ini"
CheckTCUforUpdatePackage
If this variable is set to 1, when booting, the USB interface at the front of the TCU is checked
to identify any storage medium. If, when checking the update packages, type *.usz files created
with Create MyConfig are found, then the installation of these update packages is started.
With the default setting zero, this check is skipped in order to save time.
Value:
Default:
EnableUsbShares
If this variable is set to 1, then USB memories are integrated as jointly used network drive.
If this variable is set to 0, then USB memories are integrated as individual USB data storage
device.
Value:
Default:
2.3.8
Example: Configuration file 'basesys.ini'
Configuration file basesys.ini
The following defaults are applied to the template_basesys.ini file which is supplied in the /
siemens/system/etc directory:
; ------------------------------------------------------------------
; Default Linux basesystem configuration
; ------------------------------------------------------------------
;
; section ID is for Windows compatibility and is ignored ;)
[ExternalInterface]
; If DisableCompanyNet is set to 1, the whole interface will be
disabled.
;DisableCompanyNet=1
; If ExternalIP is set, you can force the external Ethernet
; interface to use a fixed IP address etc. instead of using DHCP
; If a Hostname is set, it even overrides one received by DHCP
; Please note that only letters, digits and '-' are allowed in
Hostname;
30
0 or 1
0
0 or 1
1
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1
NCU operating system