Variables
5.10 Variable parameters
5.10
Variable parameters
Parameter overview
The following overview provides a brief explanation of the variable parameters. Subsequent
chapters contain a more detailed description.
Parameter
Variable type (Page 98)
Limits (Page 85)
Default setting (Page 103)
Toggle field (Page 101)
Texts (Page 84)
92
Description
The variable type must be specified.
R[x]:
REAL (+ digit for the decimal place)
I:
INTEGER
S[x]:
STRING (+ digit for string length)
C:
CHARACTER (individual character)
B:
BOOL
V:
VARIANT
Limit value MIN, limit value MAX
Default setting: Empty
The limit values are separated by a comma. Limits can be specified for types I, C and R
in decimal formats or as characters in the form "A", "F".
Optionally, two signal colors SC1 and SC2 can be configured for the display of a progress
bar with color change (variable attribute DT = 1) which are displayed as the respective
foreground color of the bar when the signal value SVAL1 or SVAL2 is exceeded. The
signal values are specified as integer values.
See application example for Progress bar (Page 89).
If no default setting has been configured and no system or user variable has been assigned
to the variable, the first element of the toggle field is assigned. If no toggle field has been
defined, there is no default setting, which means the status of the variable is "not calcu‐
lated".
Default setting: No default
List with predetermined entries in the IO field: The list is initiated by a *; the entries are
separated by a comma. The entries can be assigned a value.
For the toggle field, the entry for the limit is interpreted as a list. If only one * is entered,
a variable toggle field is created.
Default setting: None
The sequence is specified. Instead of a short text, an image can also be displayed.
Default setting: Empty
Long text:
Short text:
Graphic text:
Unit text:
Tooltip
Text in the display line
Name of the dialog element
Text refers to the terms in the graphics
Unit of the dialog element
Serves as brief information in a screen form configuration for
the display and toggle fields. The information is configured via
plain text and language text ID.