Siemens SIMOTICS HV M Operating Instructions Manual page 76

Electric motor
Table of Contents

Advertisement

Commissioning
7.5 Test run
4. During the test run, check and document the following:
5. In case of uneven running or abnormal noise, switch off the machine. As the machine runs
76
– Check whether it is running smoothly.
– Document the voltage, current and power values. As far as possible, document the
corresponding values of the driven machine.
– If this is possible using the available measuring equipment, check the bearing and stator
winding temperatures until they have reached steady-state values.
– Check the machine for noise or vibrations on the bearings or bearing shields as it runs.
down, identify the cause.
– If the mechanical operation improves immediately after the machine is switched off, then
the cause is magnetic or electrical.
– If the mechanical running does not improve immediately after switching the machine off,
then the cause is mechanical.
- Imbalance of the electrical machine or the driven machine
- The machine set has not been adequately aligned
- The machine is being operated at the system resonance point. System = motor, base
frame, foundation, ...
NOTICE
Serious damage to the machine
If the vibration values in operation are not maintained in accordance with DIN ISO
10816-3, then the machine can be mechanically destroyed.
● During operation, observe the vibration values in accordance with DIN ISO 10816‑3.
SIMOTICS HV M 1RN76308PR900CG0-Z
Operating Instructions 07/2018

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents