  • Page 1     Autotrol Series 255 Valve Series 263 Valve Series 268 Valve 740C-ET & 760C-ET Controllers Quick Start Manual...
  • Page 2: Logix™ Series Installer Quick-Start Sheet

    LOGIX™ SERIES INSTALLER QUICK-START SHEET LOGIX SERIES CONTROLLERS 740 Controller - Electronic time clock control capable of doing 7-day (day of week) regeneration, or up to a 99 interval day regeneration. This control will operate both in a conditioner (softener) or 3-cycle filter mode with the same controller.
  • Page 3 Step 2: Program Time of Day SU MO TU WE TH FR SA DAYS • While "12:00" is blinking, set the correct time of day. Time & Day • Use the UP and DOWN buttons to scroll to the correct time of day. •...
  • Page 4 Example: To move the cursor and select/deactivate a day 1. The cursor should be fixed. If is flashing, press SET. 2. Use UP and DOWN buttons to put the cursor under the day to change. 3. Press SET button. The cursor will flash. 4.
  • Page 5 Step 6: Set Salt Amount (Regenerant Amount) SU MO TU WE TH FR SA DAYS Time & Day • Set desired salt amount. Regen Time & Day Salt • Default setting is "S" standard salting. Capacity • 3 salt settings are available on 740 and 760 controls: Hardness Standard Salt Setting S - Standard Salt...
  • Page 6 MANUAL REGENERATION PROCEDURES To Initiate a Manual Regeneration: • Press REGEN once for delayed regeneration. System will regenerate at next set regen time (2:00 AM). A flashing regen (recycle) symbol will be displayed. • Press and hold REGEN for 5 seconds to initiate immediate manual regeneration. A solid regen symbol will be displayed.
  • Page 7 There is a check salt light on Performa Valve Identification the front of the Logix control that will illuminate when there is no regenerant present during the regenerant draw. © Copyright 2004 GE Osmonics Printed in USA P/N 1244339 Rev A...
  • Page 8 Logix 740/760 Programming Table (7-11) PROGRAM # 10 # 11 Salt Amount Setting medium high medium alto medium alto medium alto medium alto Capacity (kg CaCO Salt Amount (kg) Tank Size Resin Volume (liters) 255/268 255/268 255/268 Valve Model Injector Type Backwash I°...
  • Page 9 Logix 740/760 Programming Table (12-F) PROGRAM # 12 # 13 # 14 # 16 Salt Amount Setting medium high medium high medium high medium high Capacity (kg CaCO Salt Amount 13,1 11,3 15,0 12,0 15,0 20,0 15,4 19,0 25,0 (kg) φ...