8 COMMUNICATIONS
Table 8–6: 745 MEMORY MAP (Sheet 27 of 57)
GROUP
ADDR
DESCRIPTION
(HEX)
LOGIC
1336
Logic Input 5 Asserted State
INPUTS
1337
Logic Input 6 Function
continued
1338
Logic Input 6 Name (9 registers)
1341
Logic Input 6 Asserted State
1342
Logic Input 7 Function
1343
Logic Input 7 Name (9 registers)
134C
Logic Input 7 Asserted State
134D
Logic Input 8 Function
134E
Logic Input 8 Name (9 registers)
1357
Logic Input 8 Asserted State
1358
Logic Input 9 Function
1359
Logic Input 9 Name (9 registers)
1362
Logic Input 9 Asserted State
1363
Logic Input 10 Function
1364
Logic Input 10 Name (9 registers)
136D
Logic Input 10 Asserted State
136E
Logic Input 11 Function
136F
Logic Input 11 Name (9 registers)
1378
Logic Input 11 Asserted State
1379
Logic Input 12 Function
137A
Logic Input 12 Name (9 registers)
1383
Logic Input 12 Asserted State
1384
Logic Input 13 Function
1385
Logic Input 13 Name (9 registers)
138E
Logic Input 13 Asserted State
138F
Logic Input 14 Function
1390
Logic Input 14 Name (9 registers)
1399
Logic Input 14 Asserted State
139A
Logic Input 15 Function
139B
Logic Input 15 Name (9 registers)
13A4
Logic Input 15 Asserted State
13A5
Logic Input 16 Function
13A6
Logic Input 16 Name (9 registers)
13AF
Logic Input 16 Asserted State
13B0
Logic Input 1 Target
13B1
Logic Input 2 Target
13B2
Logic Input 3 Target
13B3
Logic Input 4 Target
GE Power Management
RANGE
745 Transformer Management Relay
8.3 MODBUS MEMORY MAP
STEP
UNITS
FORMAT
VALUE
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
FACTORY
CODE
DEFAULT
F75
1 = Closed
F30
0 = Disabled
F33
"Logic Input 6"
F75
1 = Closed
F30
0 = Disabled
F33
"Logic Input 7"
F75
1 = Closed
F30
0 = Disabled
F33
"Logic Input 8"
F75
1 = Closed
F30
0 = Disabled
F33
"Logic Input 9"
F75
1 = Closed
F30
0 = Disabled
F33
"Logic Input 10"
F75
1 = Closed
F30
0 = Disabled
F33
"Logic Input 11"
F75
1 = Closed
F30
0 = Disabled
F33
"Logic Input 12"
F75
1 = Closed
F30
0 = Disabled
F33
"Logic Input 13"
F75
1 = Closed
F30
0 = Disabled
F33
"Logic Input 14"
F75
1 = Closed
8
F30
0 = Disabled
F33
"Logic Input 15"
F75
1 = Closed
F30
0 = Disabled
F33
"Logic Input 16"
F75
1 = Closed
F46
0 = Self-Test
F46
0 = Self-Test
F46
0 = Self-Test
F46
0 = Self-Test
8-43