Electra Elite IPK II
___________________________________________________________________________________
3.3
3.4
___________________________________________________________________________________
System Hardware Manual
3.2.3
Initialization Check
To determine if the system is initializing correctly, only the Basic
KSU, CPUII( )-U( ) ETU, one ESI(8)-U( ) ETU, and terminals should
be installed on the system. After initialization, all the terminals
assigned to the ESI(8)-U( ) ETU can be used for internal calls to one
another. (By default, these stations are assigned station numbers
101~108).
System Initialization
After the steps described in Section
verified, the entire system should be initialized.
With power OFF , all interface and option cards can be installed in the basic
KSU. The technician can then power up the system to perform a First
Initialization. After the initialization, each station display shows default time
and date indications.
For example:
1 2 - 2 F r i 1 0 : 4 7 A M
After Initialization
Ensure that the battery is installed in CN6 on the
CPUII( )-U10 ETU.
Check all ETU slots in software to ensure the initialization process scanned
the installed hardware correctly.
A general system operation check should be performed using default values
prior to system programming.
After all previous steps are performed and any problems corrected, system
programming is complete.
After System Programming is finished, the technician should perform a
Second Initialization. Performing the First Initialization a second time causes
all programming memory to be lost. Second Initialization refreshes the system
RAM without losing any memory.
This completes the installation procedure for the Electra Elite IPK II system.
The technician should check the operation of each Multiline Terminal to
ensure the system is working properly.
Document Revision 3
3.2 Before Initializing
are performed and
14 - 3