Connections

Emission test
Radiated emissions - enclosure ports (30 Mhz
to 1 GHz), CISPR 16-2-3/ EN 55016-2-3
Radiated emissions - enclosure ports (1 to 3
GHz), CISPR 16-2-3/ EN 55016-2-3
Immunity test
Electrostatic discharge, IEC 61000-4-2
Radiated radio-frequency electromagnetic
field, IEC 61000-4-3
Impulse magnetic field, IEC 61000-4-9
4.7
Connections
4.7.1

Ethernet interfaces (Port1 - Port4)

Every Ethernet interface detects automatically whether the connected counterpart works as
transmission or network termination device. This way both normal and crossover cables can
be used (MDI/MDI-X).
The Ethernet interface can operate at transmission rates of 10 or 100 Mbps, depending on the
connected devices in half duplex or full duplex mode. The operation mode is detected and set
automatically by the EDS500 devices. A manual configuration is possible.
Ethernet interfaces (Port1 - Port4)
Electrical specification
Protocol
Data rate
Duplex
Transmission / Network termination
Cable
Plug type
Circuit classification
Galvanic isolation
Overvoltage protection
Electrical fast transient / Burst, IEC 61000-4-4 4 kV (level 4), criterion A
Surge 1.2/50 µs, IEC 61000-4-5
Conducted disturbances, induced by radio-
frequency fields, IEC 61000-4-6
Conducted, common mode disturbances
in the frequency range 0 Hz to 150 kHz,
IEC 61000-4-16
Conducted emissions - symetrical network
ports (0.15 MHz to 30 MHz)
30
EN 55022/ CISPR 22 class A
EN 55022/ CISPR 22 class A
8 kV air / 6 kV contact (level 3), criterion A
20 V/m (level x), criterion A
100 A/m (level 3), criterion A
IEEE 802.3
Fast Ethernet, Auto negotiation, Auto sense
100 Mbps, 10 Mbps or auto
full duplex, half duplex or auto
MDI, MDI-X or auto
shielded CAT5e cable (or better), maximum
length: 100m
RJ-45 (8P8C)
TNV-1 (acc. IEC 60950-1)
1.5 kV isolation voltage
Shield to earth ±4 kV
4 kV (level 4), criterion A
10 V (level 3), criterion A
30 V continuous disturbance/ 300 V short
duration disturbance (level 4), criterion A
EN 55032/ CISPR 32 class B
Device description