Device description
4.6

General data

General standards
Safety tested according to
Environmental conditions tested according to • ETSI EN 300 019-1-3 class 3.4
Electromagnetic compatibility (EMC) tested
according to
Environmental conditions - climatic
Nominal operating temperature range
EN 60068-2-1, EN 60068-2-2, EN 60068-2-14
Relative humidity
EN 60068-2-30
Railway applications
EN 50125-3
Environmental conditions - mechanical
Vibration sinusoidal, Test Fc , IEC 60068-2-6
Shock and Bump, Test Ea, IEC 60068-2-27
Vibration broad-band random, Test Fh,
IEC 60068-2-64
Hammer test, Test Eh, IEC 60068-2-75
1KGT150966 V000 1
• IEC 60950-1
• ETSI EN 300 019-2-8 test condition T8.1
• IEC 61850-3
• IEC 60255-21-1 class 2
• IEC 60255-21-2 class 1
• IEC 60721-3-3 class 3M5
• EN 50125-3 class T1 and T2
• IEC 61000-6-2
• IEC 61000-6-4
• ETSI EN 300 386
• EN 50121-4
• IEC 61850-3
-40 °C... 80 °C
5... 95 %
(non condensing)
climatic class T1 and T2
1.2 mm (5... 9 Hz)
4 m/s² (9... 200 Hz) 
1 octave/ min, 5 cycles per axis
EN 300 019-2-8 class T8.1
0.075 mm (10... 60 Hz)
9.8 m/s² (60... 150 Hz)
1 octave/ min, 1 cycle per axis
IEC 60255-21-1 class 2
300 m/s², 18 ms
3 shocks per direction
IEC 60721-3-3 class 3M5
50 m/s², 11 ms
100 shocks per direction
EN 300 019-2-8 class T8.1
100 m/s², 16 ms
1000 shocks per direction
IEC 60255-21-2 class 1
1.5 m/s² (5... 100 Hz)
30 min per axes
EN 300 019-2-8 class T8.1
energy: 0.2 J
General data