Advertisement

800xA Networks
NE870
User Manual

Advertisement

Table of Contents
loading

Summary of Contents for ABB NE870

  • Page 1 800xA Networks NE870 User Manual...
  • Page 3 800xA Networks NE870 User Manual...
  • Page 4 ABB products. The presence of any such description of a standard or reference to a standard is not a representation that all of the ABB products referenced in this document support all of the features of the described or referenced standard. In order to determine he specific features supported by a particular ABB product, the reader should consult the product specifications for the particular ABB product.
  • Page 5: Table Of Contents

    Table of Contents Table of Contents Safety......................7 Warning ............................7 Licensing Information ........................7 Section 1 - RNRP Router/Firewall............8 Housing........................8 2-Slot Enclosure..........................9 Power and CPU Module........................10 Power and CPU ........................11 Section 2 - Interface specifications.............12 Connection to Console Port......................14 Power Connection.........................16 I/O Connection ..........................17 LED Indicators Power/CPU ......................19 Section 3 - Interface Modules...............21 Eight Copper Ports ........................21...
  • Page 6 Notice: FCC Part 15.105......................28 Notice: Corrosive environment ....................29 Safety Control Drawing ........................29 Safety Control Drawing ........................31 Type Tests and Environmental Conditions..................32 Referring Documents ........................34 Cable Factory Reset on NE870......................34 Proceed with Factory Reset ......................34 Skip the Factory Reset ......................35 3BSE083159...
  • Page 7: Safety

    Safety Safety Warning Do not look directly into fibre optical fibre port or any connected fibre although this unit is designed to meet the Class 1 Laser regulations. When this unit is operated at an ambient temperature above 60°C, the External Surface of Equipment may exceed Touch Temperature Limit according to EN/ IEC/UL 60950-1.
  • Page 8: Section 1 Rnrp Router/Firewall

    NE870 is an industrial router which also acts as a firewall. The router/firewall can be utilized to segment a system in to network areas and also security zones. NE870 is primarily intended to be used to separate client/server networks and control networks, to separate different control and safety networks, but also to create RNRP tunnel areas between RNRP networks.
  • Page 9: 2-Slot Enclosure

    Section 1 RNRP Router/Firewall 2-Slot Enclosure Figure 1. 2-Slot Enclosure Specification Dimension W x H x D 134 x 105 x 122 mm (without connectors) Weight 1.5 kg Number of slots Degree of protection IP40 according to EN 60529 Cooling Convection Mounting Horizontal on 35 mm DIN-rail or wall-mounted...
  • Page 10: Power And Cpu Module

    Section 1 RNRP Router/Firewall Power and CPU Module Regardless of NE870 model, all units will be delivered with the power and CPU interface in the slot on the far left. The power and CPU module holds a power board and a CPU board. The isolated power supply has redundant power inputs and allows for a wide operating voltage range (refer to “Section 3 Interface...
  • Page 11: Power And Cpu

    Section 1 RNRP Router/Firewall Power and CPU • Redundant power supply and alarm function • Wide operating voltage range (16 VDC to 60 VDC) • Digital IO for monitoring • Console port for management using CLI • USB port for easy save and load system configuration •...
  • Page 12: Section 2 Interface Specifications

    Section 2 Interface specifications Section 2 Interface specifications Power and CPU Rated voltage 20 to 48 VDC Operating voltage 16 to 60 VDC Rated frequency Polarity Reverse polarity protected Redundant power input Isolation to All other Connection Detachable screw terminal Connector size 0.2 –...
  • Page 13 Section 2 Interface specifications Power Rated voltage 20 to 48 VDC Operating voltage 16 to 60 VDC Rated current 0.43 (0.60*) A @ 20 VDC 0.19 (0.25*) A @ 48 VDC Inrush current 40 mA2s @ 20 VDC 257 mA2s @ 60 VDC Startup current** 2x Rated current Rated frequency...
  • Page 14: Connection To Console Port

    Section 2 Interface specifications Connection to Console Port NE820 The console port can be used to connect to the CLI (Command Line Interface). The console connector is a micro USB cable that connects to a FTDI FT232R USB to serial converter internally. For drivers please see www.
  • Page 15 Section 2 Interface specifications Ethernet TX Electrical USB 2.0 host Electrical IEEE std 802.3. 2005 Edition specification interface specification Data rate High speed Data rate 10 Mbit/s, 100 Mbit/s, 1000 480mbit/s Mbit/s, manual or auto Circuit type SELV Duplex Full or half, manual or auto Maximum supply 500 mA Circuit type...
  • Page 16: Power Connection

    Figure 4. In/Out Directions Description Power Connection NE870 supports redundant power connection. The positive inputs are +DC1 and +DC2, the negative input for both supplies are –COM. Connect the primary voltage (e.g. +24 VDC) to the +DC1 pin and return to one of the –COM pins on the power input.
  • Page 17: I/O Connection

    The Status output is a potential free, opto-isolated normally closed solid-state relay. This can be configured to monitor various alarm events within the NE870 unit, see ABB NEOS User Manual. An external load in series with an external voltage source is required for proper functionality.
  • Page 18 Section 2 Interface specifications The Digital In is an opto-isolated digital input which can be used to monitor external events. For voltage/current ratings, see “Section 2 Interface specifications” section. External Load Status Digital In Figure 7. I/O Schema 3BSE083159...
  • Page 19: Led Indicators Power/Cpu

    Section 2 Interface specifications LED Indicators Power/CPU Figure 8. LED Indicators 3BSE083159...
  • Page 20 Section 2 Interface specifications Status Description Unit has no power GREEN All OK, no alarm condition Alarm condition, or until unit has started up. (Alarm conditions are configurable, see NEOS User Manual) BLINK Location indicator “Here I am”. Activated when connected to NECO Tool, or upon request from Web or CLI Unit has no power GREEN...
  • Page 21: Section 3 Interface Modules

    Section 3 Interface Modules Section 3 Interface Modules Eight Copper Ports All ports support category 5e cable or better and can handle cable lengths up to 150 m (492 ft). Interface Specifications 8-Copper Ports Electrical specification IEEE std 802.3. 2005 Edition Data rate 10 Mbit/s or 100 Mbit/s, Manual or Auto Duplex...
  • Page 22: Led Indicators 8-Copper Ports

    Section 3 Interface Modules LED Indicators 8-Copper Ports Status Description Copper ports 1 – 8 OFF No Link GREEN Link established GREEN FLASH Data traffic indication YELLOW Port alarm and no link. Or if FRNT, RSTP or Link Aggregation mode, port is blocked. Position Direction* Description...
  • Page 23: Mounting

    “Figure 10. Mounting, 35 mm DIN-rail”. Figure 10. Mounting, 35 mm DIN-rail For proper vibration and chock performance ABB recommends standard top-hat DIN-rail TH 35-15 according to EN 60715. Removal Press down the support at the back of the unit using a screwdriver as shown in...
  • Page 24: Earth Connection

    Section 3 Interface Modules Figure 11. Removing 35 mm DIN-rail Figure 12. Wall Mounting the Unit Earth Connection For correct function the ground connection on the unit needs to be properly connected to a solid ground as shown in “Figure 13. Earth Connection”.
  • Page 25 Section 3 Interface Modules NE870 +DC1 +DC2 CONSOLE F=FRNT R=RSTP U=USR1 Figure 13. Earth Connection Spacing is recommended for the use of unit in full operating temperature range and service life as shown in “Figure 14. Cooling”. 3BSE083159...
  • Page 26: Getting Started

    Figure 14. Cooling Getting Started This product runs ABB Network Equipment Operating System (NEOS) which provides several management tools that can be used for configuration of the unit. NECO - is a Network configuration management tool made for commissioning and maintenance of components in a network.
  • Page 27: Configuration

    Section 3 Interface Modules For advanced network settings and more diagnostic information, please use the CLI. Detailed documentation is available in the chapter The Command Line Management Tool in the NEOS User Manual. Factory default: – IP address: 172.16.5.245 – Netmask: 255.255.252.0 –...
  • Page 28: Agency Approvals And Standards Compliance

    Section 3 Interface Modules Agency Approvals and Standards Compliance ABB Article Denomination Type Approval / Compliance Number 3BSE080208R1 NE870 EN 61000-6-1, Electromagnetic compatibility – Immunity for residential environments EN 61000-6-2, Electromagnetic compatibility – Immunity for industrial environments EN 61000-6-3, Electromagnetic compatibiliy –...
  • Page 29: Notice: Corrosive Environment

    Section 3 Interface Modules Notice: Corrosive environment This product has been successfully tested in a corrosion test according to IEC 60068-2-60, method 3. This means that the product meets the requirements to be placed in an environment classified as ISA-S71.04 class G3. Note! If the product is placed in a corrosive environment, it is important that all unused connector sockets are protected with a suitable plug in order to avoid corrosion attacks on the gold plated pins in connectors.
  • Page 30 Section 3 Interface Modules Position Direction/description Input/Output values In/Out / BI_DA+ Per port: U = ± 1 V (4V/us) In/Out / BI_DA– NE820 I = ± 20 mA In/Out / BI_DB+ Data rate: In/Out / BI_DC+ 10/100/1000 Mbit/s In/Out / BI_DC– In/Out / BI_DB–...
  • Page 31: Safety Control Drawing

    Section 3 Interface Modules Safety Control Drawing Position Direction*/description Input/Output values Per port: In/Out / TD+ U = ± 1 V (4V/us) I = ± 20 mA In/Out / TD– Data rate: In/Out / RD+ 10/100 Mbit/s Not connected Not connected In/Out / RD–...
  • Page 32: Type Tests And Environmental Conditions

    Section 3 Interface Modules Type Tests and Environmental Conditions Environmental Test Description Test levels phenomena EN 61000-4-2 Enclosure contact ±6 kV Enclosure air ±8 kV RF field AM IEC 61000-4-3 Enclosure 20 V/m 80% AM (1 kHz), 80–2700 MHz modulated 10V/m 80% AM (1 kHz), 2700-6000 MHz Fast transients EN 61000-4-4 Power port...
  • Page 33 Section 3 Interface Modules Dielectric strength EN 60950 Power port to all 1.5 kVrms, 50 Hz, 1 min other ports Signal ports to all 1.5 kVrms, 50 Hz, 1 min other ports Temperatures Operating –40 to +70°C (–40 to +158°F) Storage and –50 to +85°C (–58 to +185°F) transport...
  • Page 34: Referring Documents

    3BSE034463 en Guide Configuration Guide Cable Factory Reset on NE870 It is possible to set the unit to factory default settings by using two straight standard Ethernet RJ-45 cables. 1. Power off the switch and disconnect all Ethernet cables (copper and fibre).
  • Page 35: Skip The Factory Reset

    Section 3 Interface Modules Skip the Factory Reset To skip the factory reset process, just wait for approximately 30 seconds (after the ON LED starts flashing RED) without unplugging the Ethernet cables. The switch will conduct a normal boot with the existing settings. Do not power off the unit while the factory reset process is in progress.
  • Page 36 Contact us www.abb.com/800xA Copyright© 2017 ABB. www.abb.com/controlsystems All rights reserved.

Table of Contents