Operating instruction
Operating instruction
Modem 50-2400 baud 500FSD20
Modem 50-2400 baud 500FSD20
EDS500 series - FSK modems
EDS500 series - FSK modems
Application, characteristics and technical data have to
be taken from the hardware data sheet:
500FSD20 Data sheet 1KGT150986
Operation
The 500FSD20 modem is a voice-frequency telegraphy
unit (VFT unit) which operates according to the
principle of binary frequency shift keying. The modem
can operate in two- and four-wire connection. The
mode of operation is set by a command line interface
(CLI).
Connections
Power connector (X1)
The EDS500 devices are equipped with a wide range
power supply for voltages between 24 and 60 Volts DC
(power consumption see device label). The connector
is a 3-pin Phoenix plug with screw terminals.
Pin allocation power supply (X1)
1
Due to the internal overvoltage protection,
interrupt any connection to ground of the device
for the time of the measurement before you carry
out isolation measurements. This includes the
earthing of the hat rail as well as all shields of all
transmission lines and supply feedings. RJ-12 plugs
or RJ-45 plugs can also establish earthing via the
shield.
Serial interface to DTE (X2)
The RJ-45 connector X2 forms an RS-232-D interface. If
the modem is connected to an RTU, an adapter cable
has to be used which connects the pin pairs.
Pin allocation serial interface DTE (RJ-45)
Pin
Signal
2
3
1
24-60 V DC
2
Functional earth
3
GND
A D V I C E
RS-232-D
Pin
Signal
V.24
8
1
1
DSR M1
Pin allocation serial interface DTE (RJ-45)
Interface to transmission line (X3)
In two-wire mode X3-1 and X3-2 form terminal NF1
which is used for transmission and reception.
In four-wire mode X3-1 and X3-2 form the transmitter
terminal NF1 and X3-3 and X3-4 form the receiver pair
NF2.
NF terminals
2-wire
4-wire
Pin allocation transmission line interface (X3)
1
Serial interface for configuration (Con0)
The serial interface of the device is signal compatible
to RS-232. The connector is an RJ-12 female plug. The
factory presets are speed 57600 Baud, no parity, 1
stop bit, no flow control. Via the serial interface the
management console can be accessed .
Pin allocation serial interface RS-232 (RJ-12)
Signal
Direction
V.28
107
output
2
DCD M5
3
DTR S1
4
GND
5
RxD C2
6
TxD D1
7
CTS M2
8
RTS S2
Transmit
NF1: X3-1 and X3-2
NF1: X3-1 and X3-2
Pin
Signal
1
NF1a
2
NF1b
3
NF2a
2
3
4
4
NF2b
RS-232
Pin Signal Direction Pin Signal Direction
1
DCD Output
2
CTS
Output
3
RTS
Input
6
1
4
GND -
5
RxD
Output
6
TxD
Input
109
output
108.2
input
GND
-
104
output
103
input
106
output
105
input
Receive
NF1: X3-1 and X3-2
NF2: X3-3 and X3-4
RS-232 PC SUB-D9
1
DCD Input
8
CTS
Input
7
RTS
Output
5
GND -
2
RxD
Input
3
TxD
Output

Advertisement

loading

Summary of Contents for ABB EDS500 Series

  • Page 1 Operating instruction Operating instruction Modem 50-2400 baud 500FSD20 Modem 50-2400 baud 500FSD20 EDS500 series - FSK modems EDS500 series - FSK modems Application, characteristics and technical data have to Pin allocation serial interface DTE (RJ-45) be taken from the hardware data sheet:...
  • Page 2 Alarm relay (X4) Description Function The devices are equipped with a potential free alarm Con0 Con0 No activity on the output (relay with isolated switchover contact). This activity Con0 interface output corresponds to a device alarm and is activated green Data is trans- when the device looses the power supply or the alarm mitted via Con0...
  • Page 3 Configuration commands entered on the PC via a serial cable, open a command window • command line interface are stored in the running in Windows on that PC. Change the directory configuration of the device, which represents the to the path containing the firmware image and current state of the system.
  • Page 4: Installation

    "Fig. 4: Schematic installation drawing" shows a W A R N I N G schematic drawing of the correct installation of the No plug shall be freely accessible in normal modem. X1-2 has to be connected to functional earth. operation due to safety reasons. Terminal X1-1 is connected to the positive terminal and X1-3 to the negative terminal of a DC power supply.
  • Page 5 Figure 3: 500FSD20 Label Figure 2: 500FSD20 Front plate Figure 1: 560FSD20 1 2 3 Connect DIN-rail to Protection earth 1 2 3 4 Figure 4: Schematic installation drawing NF2a NF2b NF1a NF1b Figure 5: Communication line connection by LF transformer (two-wire connection)
  • Page 6 ABB Power or in parts – is forbidden without prior written Grids Germany AG does not accept any consent of ABB Power Grids Germany AG. responsibility whatsoever for potential Copyright© 2019 ABB Power Grids Germany AG errors or possible lack of information in All rights reserved www.abb.com/remote-terminal-units...

This manual is also suitable for:

Eds 500fsd20