Configuring with Web Based Management
6.10 "iFeatures" menu
6.10.2

iPCF-HT

Note
This WBM page can only be configured with the following KEY-PLUGs:
• Access point: W780 iFeatures (MLFB 6GK5 907-8PA00)
• Client: W740 iFeatures (MLFB 6GK5 907-4PA00)
When should iPCF-HT (High Throughput) be used?
Note
Use of iPCF-HT
The function iPCF-HT
• and other iFeatures (e.g. iPCF, iPCF-MC, iPRP) are not compatible with each other and
cannot be used at the same time on a device.
• Can only be used in the frequency band 5 GHz and with WLAN mode "(only) IEEE
802.11n".
• Is available only on the WLAN interface 1.
It is advisable only to use and MCS index.
The use of iPCF-HT is particularly advisable when a higher data throughput is required. If,
for example, alongside PROFINET you also want to transfer video data. The real-time
behavior for PROFINET is retained.
The possible settings differ for access point and client.
408
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 08/2018, C79000-G8976-C267-13