Description
The table has the following columns:
● Port
Shows the available interfaces.
– VAP X.Y (in access point mode)
– WLAN 0/X (in client mode)
● Destination Address / State
Shows which destination address is monitored and the status of the connection. You
configure the destination address in "Interfaces > WLAN > Force Roaming".
– not configured: No destination address is configured.
– idle: The configuration is incomplete.
– up:The destination address is reachable.
– down: The destination address is unreachable.
● Force Roaming on IP down
Indicates whether roaming is currently being performed.
– Inactive: No roaming is being performed. No change to the WLAN interface.
– Active: None of the destination addresses is reachable. To force the logged on clients
6.4.14.6

Overview Client

Overview of the configuration
Note
This page is only available for clients or access points in client mode.
The page shows an overview of the existing clients and their configuration.
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 08/2018, C79000-G8976-C267-13
/ connected access points to roam, the device has disabled the corresponding
interface.