8.6

WLAN client Trigger handover via SNMP

If the other handover mechanisms such as Roaming threshold value, Background Scan
threshold value are inadequate, a specific handover can be triggered by setting the MIB
variable snMspsWlanForceHandover.
A WLAN client drives, for example along a stretch where there are several access points.
When the WLAN client passes a certain point, the value of the MIB variable is changed from
0 to 1. The WLAN client logs off from the connected access point and searches for
reachable access points. It logs on to the best reachable access point. The value of the MIB
variable is reset to 0.
Trigger handover
Using the private MIB variable snMspsWlanForceHandover, you can force a handover.
Note
With Web Based Management (WBM) or using the Command Line Interface (CLI) you
cannot configure this function.
OID of the private MIB variable snMspsWlanForceHandover:
iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).siemens(4329).industrialCo
mProducts(20).iComPlatforms(1).simaticNet(1).snMsps(1).snMspsCommon(1).snMspsWlan(27)
.snMspsWlanObjects(1). snMspsWlanSmt(1). snMspsWlanRoamingConfigTable(4). snMspsWlanR
oamingConfigEntry(1). snMspsWlanForceHandover(14)
values of the MIB variable
● 0: Function is disabled.
● 1: Triggers handover.
MIB file
The MIB variable snMspsWlanForceHandover can be found in the private MIB file
"Scalance_w_msps.mib".
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 08/2018, C79000-G8976-C267-13
8.6 WLAN client Trigger handover via SNMP
Troubleshooting/FAQ
439