Issue 0.1
Program 81 : Basic Hardware Setup for Trunk
Level
IN
Description
Use Program 81-08 : T1 Trunk Timer Setup to define the basic timer setting of each T1 Trunk type.
Input Data
Item
01
Answer Signal Detection Time (Loop)
02
Answer Signal Detection Time (Ground)
03
Answer Signal Detection Time (DID)
04
Answer Signal Detection Time (E&M)
05
Answer Signal Detection Time (OPX)
06
Clear Signal Detection Time (Loop)
07
Clear Signal Detection Time (Ground)
08
Clear Signal Detection Time (DID)
09
Answer Signal Detection Time (E&M)
10
Clear Signal Detection Time (OPX)
11
Ringing Signal Detection Time (Loop)
12
Ringing Signal Detection Time (Ground)
13
Ringing Signal Detection Time (DID)
14
Ringing Signal Detection Time (E&M)
15
Ringing Signal Detection Time (OPX)
16
Ringing Signal Stop Detection Time (Loop)
17
Ringing Signal Stop Detection Time
(Ground)
18
Ringing Signal Stop Detection Time (DID)
19
Ringing Signal Stop Detection Time (E&M)
20
Ringing Signal Stop Detection Time (OPX)
21
Loop Current Detection Time (Loop)
Programming Manual
Name
1~250 (4 ms ~ 1000 ms)
1~250 (4 ms ~ 1000 ms)
1~250 (4 ms ~ 1000 ms)
1~250 (4 ms ~ 1000 ms)
1~250 (4 ms ~ 1000 ms)
1~255 (100 ms ~ 25500 ms)
1~255 (100 ms ~ 25500 ms)
1~255 (100 ms ~ 25500 ms)
1~255 (100 ms ~ 25500 ms)
1~255 (100 ms ~ 25500 ms)
1~250 (8 ms ~ 2000 ms)
1~250 (8 ms ~ 2000 ms)
1~250 (8 ms ~ 2000 ms)
1~250 (8 ms ~ 2000 ms)
1~250 (8 ms ~ 2000 ms)
1~255 (100 ms ~ 25500 ms)
1~255 (100 ms ~ 25500 ms)
1~255 (100 ms ~ 25500 ms)
1~255 (100 ms ~ 25500 ms)
1~255 (100 ms ~ 25500 ms)
1~250 (4 ms ~ 1000 ms)
81-08 : T1 Trunk Timer Setup
Input Data
SL1000
Program
81
Default
15
60 ms
15
60 ms
15
60 ms
15
60 ms
15
60 ms
6
600 ms
6
600 ms
6
600 ms
6
600 ms
6
600 ms
10
80 ms
10
80 ms
10
80 ms
10
80 ms
10
80 ms
50
5000 ms
50
5000 ms
50
5000 ms
50
5000 ms
50
5000 ms
40
160 ms
2-423