Module
SME20
SME120 /
SME125
Active Line Module
Smart Line Module
Basic Line Module
Motor Module
Cable for connection to direct measurement systems: Order number 6FXx002-2CB54-xxxx
1)
Commissioning Manual
Commissioning Manual, (IH1), 01/2012, 6SL3097-4AF00-0BP2
Interface
Pin
X535
1
2
3
4
X536
1
2
3
4
Measuring system
7
interface
9
X200 (connector)
1
Temperature
2
channel 2
X200 (connector)
3
Temperature
4
channel 3
X200 (connector)
5
Temperature
6
channel 4
Booksize
1
X21 (terminal)
2
Chassis
4
X41 (terminal)
3
Booksize
1
X21 (terminal)
2
Chassis
4
X41 (terminal)
3
Booksize
1
X21 (terminal)
2
Chassis
4
X41 (terminal)
3
Booksize
1
X21/X22 (terminal)
2
The following
4
applies to chassis:
3
X41 (terminal)
2.16 Temperature sensors for SINAMICS components
Signal name
Technical specifications
+Temp
- Temp
+Temp
- Temp
+Temp
- Temp
+Temp
- Temp
- Temp
Temperature sensor
+Temp
KTY84-1C130 / PTC
connection cable order number
6FX8002-2CA88- xxxx necessary
1)
- Temp
Temperature sensor
+Temp
KTY84-1C130 / PTC / bimetallic
switch with NC contact
+Temp
Temperature sensor
- Temp
KTY84-1C130 / PTC / bimetallic
switch with NC contact
+Temp
Temperature sensor
- Temp
KTY84-1C130 / PTC / bimetallic
switch with NC contact
+Temp
Active Line Module temperature
- Temp
sensor
Temperature switch type:
+Temp
bimetallic switch with NC contact
- Temp
+Temp
Active Line Module temperature
- Temp
sensor
Temperature switch type:
+Temp
bimetallic switch with NC contact
- Temp
+Temp
Basic Line Module temperature
- Temp
sensor temperature switch type:
bimetallic switch with NC contact
+Temp
- Temp
+Temp
Temperature sensor
- Temp
KTY84–1C130 / PTC
Bimetallic switch with NC contact:
+Temp
Alarm and timer (only for
- Temp
temperature evaluation via MM)
PT100 temperature sensor
Commissioning
173