Panasonic LP-GS Series Serial Communication Command Manual page 97

Laser marker lp-400/v compatible mode
Hide thumbs Also See for LP-GS Series:
Table of Contents

Advertisement

6. When the code type is GS1 DataBar Stacked
When the code type is GS1 DataBar Stacked CC-A and specify its 1D side settings
Name
Data length
(> Name in LP-400/V)
Object No.
(> Bar code No.)
System reserved
value
(Area No.)
Code type
Human readable text
Invert
and
left/right guard
pattern width to
module width ratio
Lower barcode
height
Separator height to
module width ratio
Module width
X-position
Y-position
Rotation angle
Laser power
correction
Scan speed
correction
Pulse cycle
correction *
Total data length
* Only for LP-RF series and LP-RV series.
• With LP-400/V compatible command mode, "Code marking direction" cannot be set. To this item the setting by Laser
Marker NAVI smart or the initial value if it was not set, is applied.
• With LP-400/V compatible command mode, it is not possible to set the arbitrary value to "Left guard width to module
width ratio" and "Right guard width to module width ratio".
Data contents
[byte]
1
"0"–"7": Object No. 1100 to 1107
1
"0"–"9", "A"–"F"
"31": GS1 DataBar Stacked
2
"41": GS1 DataBar Stacked CC-A
"0": OFF
1
"2": ON
Setting
Invert
"0"
Not invert
1
"1"
Invert
"2"
Invert
Model
LP-GS051(-L)
LP-GS052
7
LP-RC350S
LP-RF200P
LP-RV200P
4
"00.0"–"10.0"
5
"0.050"–"1.000" [mm]
8
"-999.999"–"+999.999" [mm]
8
7
"-180.00"–"+180.00" [°]
3
"000"–"999" [%]
3
"001"–"999" [%]
(3)
"001"–"999" [%]
47
The data length is fixed.
or
• LP-GS/LP-RC series: 47-byte
50
• LP-RF/LP-RV series: 50-byte
ME-LP-GS-SR-COMP-3
This value does not affect the settings
anymore.
For the composite codes, this setting is
applied to both 1D and 2D side.
• Set "0" to mark a bar, "1" or "2" to
Left/right guard width
• When the inversion is enabled,
to module ratio
1.0, 1.0
• The readout value is always "2"
1.0, 1.0
2.0, 2.0
Setting range [mm]
In Laser Marker NAVI smart, this
"000.050"–"055.000"
setting is converted to the height ratio
"000.050"–"030.000"
of the lower side to module width and
"000.050"–"085.000"
displayed as "Lower barcode height to
module width ratio".
"000.050"–"090.000"
Specifies the ratio of GS1 DataBar
Stacked separator to module width.
Specify a larger value than the line
width in the object group settings.
• It is the center coordinate of the
• The rotation center is the center of
• The correction ratio is calculated
• At LP-400/V compatible command
Remarks
mark a space.
select the left/right guard pattern
width to module width ratio.
when the inversion is enabled,
regardless the settings of left/right
guard pattern.
code.
the code symbol.
using the value set at the laser
settings as 100%.
mode, the same correction values
are applied to the separator.
97

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents