ERROR
CODE
Lasing operation/shutter open operation was
cancelled due to a timeout after the laser start-
up check.
Try again.
E640 *3
(Details: For the first operation of opening shutter
E641 *3
or lasing after the laser pumping on, warning
E640/E641 may occur and the requested
operation is canceled in case the laser pumping
has been off for more than several days and time
for laser start-up check (maximum 30 seconds)
is needed.)
Font file data are incorrect. Unable to read the
E652
font file.
Graphic file data are incorrect. Unable to read
E653
the graphic file.
Font file is not registered to the font No.
E654
specified.
Insufficient font memory. Font file data capacity
E655
is too large.
E656
The specified graphic data are not registered.
No font corresponding to set characters were
E657
found.
E658
Too large number of characters.
E659
Existed invalid character for bolding with setting.
Bold characters cannot be created due to the
E660
combination of set bold line width, character
height, and character width.
158
Description
ME-LP-GS-SR-COMP-3
Measures *1
• When operating with Laser Marker NAVI smart,
retry to start test marking/laser radiation for
measurement/run mode operation.
• When operating in remote mode, close the shutter
or input the alarm reset to recover from the
warning status, and then retry opening the shutter
or laser radiation for measurement.
• Re-register font data on the data management
screen.
• Check the font data file format.
• Re-register graphic data on the data management
screen.
• Check the graphic data file format.
• Register the font file on the data management
screen.
• Using the character conditions, specify the font
No. in which the font file is registered.
• Reduce the number of characters registered in the
font file.
• Delete unnecessary font files.
Register the graphic file in the data management
screen.
• Change characters, or add the font data in use.
• To use Japanese or Simplified Chinese
characters, set "East Asian characters" in file
settings.
• Decrease the number of characters.
• Set the characters by separating them into several
objects.
• Original4 font cannot be displayed in bold. Select
another font.
• Use Font Maker software provided to create the
proper pattern font.
• Set the bold line width to half or less of the
character height or the character width, whichever
is smaller.
• When marking the bold character, set the
comparison ratio between character height and
width at 1/10 to 10.