10. After that, on the left screen click on sign + to left of DRIVE and then on expert list. In this way you
will display all the parameters both reading and writing of the inverter.
Figure 45 – STARTER visualization of all parameters both reading (yellow) and writing (green)
11. To display only the parameters of interest for the setting of the inverter, apply one of the available
filters. For more details, see also chapter 10.1.
if the lists are not available, you can copy them from the same folder of another project (...\u7\cdldate
t) , or ask directly to OMARLIFT.
12. The modification of the parameters of interest (only those in green field, by the letter P) takes places
by disconnecting from inverter (OFFLINE mode), clicking -always in OFFLINE mode- on the value of
interest, typing the new number and pressing ENTER. At the end of the parameters change, press
the Save project button to save the new configuration.
at this point, the modified program is saved only on the PC and is NOT operating on the
INVERTER yet.