These systems use a single filter pump and filter. Pool or spa operation is controlled by two 3-way valves (suction and return). Refer to the diagram below.
High Voltage Relays
Filter Pump
Lights
Aux 1
Aux 2
POOL/SPA SUCTION
VALVE
CHECK VALVE
(prevents draining
of raised spas)
MANUAL
VALVE
POOL VACUUM
VALVE
SKIM
MAIN
DRAIN
SUCTION
CLEANER
Some important notes regarding standard Pool/Spa systems:
1.
The OmniLogic can be programmed to accommodate spa spillover, if desired.
2.
A conventional heater (gas or heat pump) and solar can be used to heat both the pool and the spa.
3.
If the chlorinator cell is plumbed prior to the pool/spa return valve, then both the pool and the spa can be chlorinated
4.
The water sensor should be installed prior to any heater or solar and will display either the pool or the spa temperature, depending on the current operation
of the pool. The temperature will only be displayed when the filter pump is running.
5.
If any water feature or pressure side cleaner boost pumps are used, be sure to enable the "interlock" feature (see CONFIGURATION for details) to ensure
that the pumps operate only when the filter pump is on and the system is in the "pool only" operating mode.
6.
The plumbing diagram above is intended to be used as a general guideline and is not a complete plumbing schematic for the pool.
7.
The air sensor must be installed if the freeze protection feature is enabled for the filter, valves, chlorinator, other pool functions.
Need help?
Do you have a question about the OmniLogic and is the answer not in the manual?
Questions and answers
How bad 4A fuse transformer & cell circuit affects the valves actuator not working.
Can the hayward flow switch be plumbed in vertically or does it have to be horizontal?