Term
Remote register (RWr)
Remote register (RWw)
Reserved station
Return
RnENCPU
RnENCPU (CPU part)
RnENCPU (network part)
Routing
Safety CPU
Shared group number
SIL2 function module
SIL2 Process CPU
SIL2 mode
Slave station
Standby system
Submaster operating station
Submaster station
Subnet mask
System switching
Tracking cable
Transient transmission
Transient transmission group number
16
Description
Word data input from a slave station to the master station of CC-Link IE Field Network (For some areas
in a local station, data are input in the opposite direction.)
Word data output from the master station to a slave station of CC-Link IE Field Network (For some
areas in a local station, data are output in the opposite direction.)
A station reserved for future use. This station is not actually connected on CC-Link IE, but counted as a
connected station.
A process of restarting data link when a station recovers from an error
A generic term for the R04ENCPU, R08ENCPU, R16ENCPU, R32ENCPU, and R120ENCPU
A module on the left-hand side of the RnENCPU ( Page 23 CPU Module)
A module on the right-hand side of the RnENCPU ( Page 23 CPU Module)
A process of selecting paths for communication with other networks. There are two types of routing:
dynamic routing that auto-selects the communication routes, and static routing where communication
routes are arbitrarily set.
A generic term for the R08SFCPU, R16SFCPU, R32SFCPU, and R120SFCPU.
Number that is assigned to a station to allow it to share cyclic data with any given stations on CC-Link IE
Controller Network.
Cyclic data can be shared only with stations of the same group.
Another name for the R6PSFM.
This module is used with the SIL2 Process CPU as a pair and performs safety control. The module can
only be paired with the SIL2 Process CPU.
A generic term for the R08PSFCPU, R16PSFCPU, R32PSFCPU, and R120PSFCPU.
This module is used with a SIL2 function module as a pair, and performs both standard control and
safety control. This module is also used with a redundant function module as a pair and configures a
redundant system.
An operation mode of the I/O module and the intelligent function module to perform safety input and
output at the SIL2 level. For details on the SIL2 mode, refer to the following.
 Manuals for the I/O module or the intelligent function module used
A generic term for a local station, remote I/O station, remote device station, and intelligent device
station of CC-Link IE Field Network
A backup system in a redundant system
A station that monitors a master operating station when the submaster function of CC-Link IE Field
Network is used. Only one master station can be used in a network.
A station that serves as a master station to control the entire network if the master station of CC-Link IE
Field Network is disconnected. Only one master station can be used in a network.
A number used to logically divide one network into multiple subnetworks and manage them easily. The
following Ethernet network systems can be configured:
• A small-scale Ethernet network system in which multiple network devices are connected
• A medium- or large-scale network system in which multiple small-scale network systems are
connected via routers or other network communication devices.
A function which switches the systems between the control system and the standby system to continue
operation of the redundant system when a failure or an error occurs in the control system
An optical fiber cable used to connect two redundant function modules in a redundant system
A function of communication with another station, which is used when requested by a dedicated
instruction or the engineering tool
Number that is assigned for transient transmission to any given stations on Ethernet and CC-Link IE
Controller Network.
By specifying a group of stations as transient transmission target, data can be sent to the stations of the
same group number.