Replacing The Fan (R7) - ABB ACS800-U4 Hardware Manual

Drive modules (90 to 500 kw) drive modules (125 to 600 hp)
Hide thumbs Also See for ACS800-U4:
Table of Contents

Advertisement

80

Replacing the fan (R7)

1. Remove the front cover.
2. Disconnect the discharging resistor wire.
3. Remove the DC capacitor pack by undoing the red fixing screws and pulling the
pack out.
4. Disconnect the fan supply wires (detachable connector).
5. Disconnect the fan capacitor wires.
6. Disconnect the AINP board wires from connectors X1 and X2.
7. Undo the red fixing screws of the fan cassette.
8. Press the snap-on holders to release the side cover.
9. Lift the handle and pull the fan cassette out.
Install the fan in reverse order to the above and renew the fan capacitor.
4
3
3
3
Maintenance
3
3
2
3
3
DC+
DC-
6
7
9
5
7
8
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acs800-04

Table of Contents