Measures for Indicated Error

The following operations occur when any error occurs on the laser marker.
1 . " E**" is displayed on the "File No./Error Code" display part in the front panel of the head.
2 . The error output of the I/O connector is ON.
This section describes the details and measures of the error code indications in the front panel of the head.
Error
Error Indication
Code
Remote interlock
E01
connector OPEN
Laser radiation stop
E02
input OPEN
E04
No marking file
Remote interlock
E10
connector OPEN
during marking
Laser radiation stop
E11
input during marking
Shutter operation
E12
during marking
E20
Cover OPEN
E21
X/Y galvanometer
E22
error
E23
Laser tube error
E25
Marking file error
E26
Area over
E30
System error
E31
to
System error
E39
E90
Internal communication
to
error
E99
Cause
The remote interlock connector
for the power supply BOX is
opened.
The laser radiation stop
input signal is transmitted
from the I/O connector.
No marking file is existed.
The remote interlock connector
of the power supply BOX is
opened during marking.
The laser radiation stop input
signal was transmitted from
the I/O connector during
marking.
The shutter operation is
occurred during marking.
The cover of the head is
opened.
An error is detected on the
galvanometer.
The data is located out of
the marking area.
An error is detected on the
laser mechanism.
An error is detected on the
marking file.
The data is located out of
the marking area.
Detected a decrease in
power supply voltage for
the back up battery.
An error is detected on the
laser marker.
An error is detected in the
communication in the prod-
uct.
Measure
Short-circuit the remote interlock connector for
the power supply BOX.
Turn ON the laser radiation stop input from the
I/O connector.
Confirm the marking file.
Confirm the file selection input of the I/O con-
nector.
Short-circuit the remote interlock connector of the
power supply BOX, and then turn on the key
switch again.
Turn ON the laser radiation stop input from the
I/O connector, and then turn on the key switch
again.
Turn on the key switch again.
Contact our sales office.
Contact our sales office.
Confirm the position of the setting data, and if
required, move the data into the marking area.
Contact our sales office.
Contact our sales office.
Confirm the position of the setting data, and if
required, move the data into the marking area.
Leave the laser marker with "E30" error status
in a few minutes to charge the back up battery.
Then, restart the laser marker twice. (Keep 5
seconds or more in the each OFF status.)
After the recovery of the error, set the following
parameters with PC setting software.
1. Set the date and time of the laser marker on
the environment setting screen.
2. Transfer the file data again.
* In case using LP-ADP30, set the offset value
again.
Contact our sales office.