2 PRODUCT DESCRIPTION
c) ORDER CODES WITH PROCESS BUS MODULES
The order codes for units with the process bus module are shown below.
Table 2–4: N60 ORDER CODES (WITH PROCESS BUS)
N60
-
*
**
- *
*
* - F
BASE UNIT
N60
|
|
|
|
|
CPU
E
|
|
|
|
J
|
|
|
|
K
|
|
|
|
N
|
|
|
|
S
|
|
|
|
SOFTWARE
00
|
|
|
(IEC 61850 options
03
|
|
|
06
|
|
|
not available with
07
|
|
|
type E CPUs)
14
|
|
|
15
|
|
|
16
|
|
|
17
|
|
|
MOUNT/COATING
H
|
|
A
|
|
FACEPLATE/ DISPLAY
C
|
D
|
A
|
P
|
G
|
B
|
K
|
M
|
Q
|
U
|
L
|
N
|
T
|
V
|
POWER SUPPLY
H
L
PROCESS BUS MODULE
DIGITAL
INPUTS/OUTPUTS
INTER-RELAY
COMMUNICATIONS
(select a maximum of 1 per unit)
Replacement modules can be ordered separately as shown below. When ordering a replacement CPU module or face-
plate, please provide the serial number of your existing unit.
Not all replacement modules may be applicable to the N60 relay. Only the modules specified in the order codes are
available as replacement modules.
NOTE
Replacement module codes are subject to change without notice. CPU modules 9G, 9H, 9L, and 9M are obsolete.
See
http://www.gedigitalenergy.com/multilin/order.htm
NOTE
GE Multilin
N60 Network Stability and Synchrophasor Measurement System
**
- H
**
- M
**
- P
**
- U
**
- W/X
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
81
|
|
|
XX
XX
XX
XX
4L
4L
67
67
6C
6C
6D
6D
6E
6E
6F
6F
6P
6P
6R
6R
6S
6S
6T
6T
6U
6U
6V
6V
**
Full Size Horizontal Mount
|
Base Unit
|
RS485 and RS485
|
RS485, multi-mode ST 100Base-FX and 10/100Base-T
|
RS485, multi-mode ST redundant 100Base-FX and 10/100Base-T
|
RS485 and 10/100Base-T
|
RS485 and six-port managed Ethernet switch
|
No software options
|
IEC 61850
|
Phasor measurement unit (PMU)
|
IEC 61850 and phasor measurement unit (PMU)
|
Two phasor measurement units (PMUs); requires at least one CT/VT module
|
IEC 61850 and two phasor measurement units (PMUs); requires at least one CT/VT module
|
Four phasor measurement units (PMUs); requires at least two CT/VT modules
|
IEC 61850 and four phasor measurement units (PMUs); requires at least two CT/VT modules
|
Horizontal (19" rack)
|
Horizontal (19" rack) with harsh environmental coating
|
English display
|
French display
|
Chinese display
|
English display with 4 small and 12 large programmable pushbuttons
|
French display with 4 small and 12 large programmable pushbuttons
|
Chinese display with 4 small and 12 large programmable pushbuttons
|
Enhanced front panel with English display
|
Enhanced front panel with French display
|
Enhanced front panel with Russian display
|
Enhanced front panel with Chinese display
|
Enhanced front panel with English display and user-programmable pushbuttons
|
Enhanced front panel with French display and user-programmable pushbuttons
|
Enhanced front panel with Russian display and user-programmable pushbuttons
|
Enhanced front panel with Chinese display and user-programmable pushbuttons
|
125 / 250 V AC/DC power supply
|
24 to 48 V (DC only) power supply
|
Eight-port digital process bus module
XX
No Module
|
14 Form-A (no monitoring) Latchable outputs
|
8 Form-A (no monitoring) outputs
|
8 Form-C outputs
|
16 digital inputs
|
4 Form-C outputs, 8 digital inputs
|
8 Fast Form-C outputs
|
6 Form-A (current with optional voltage) outputs, 4 digital inputs
|
2 Form-A (no monitoring) and 2 Form-C outputs, 8 digital inputs
|
2 Form-A (no monitoring) and 4 Form-C outputs, 4 digital inputs
|
4 Form-A (no monitoring) outputs, 8 digital inputs
|
6 Form-A (no monitoring) outputs, 4 digital inputs
|
2 Form-A outputs, 1 Form-C output, 2 Form-A (no monitoring) latching outputs, 8 digital inputs
2G
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 1 Channel
2H
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 2 Channels
73
1550 nm, single-mode, LASER, 2 Channel
77
IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 2 Channels
7H
820 nm, multi-mode, LED, 2 Channels
7I
1300 nm, multi-mode, LED, 2 Channels
7M
Channel 1 - RS422; Channel 2 - 1300 nm, multi-mode, LED
7S
G.703, 2 Channels
7V
RS422, 2 Channels, 2 Clock Inputs
7W
RS422, 2 Channels

2.1.3 REPLACEMENT MODULES