System information
The following table lists the special relay areas relating to the system information.
No.
Name
SM203
STOP contact
SM230
Remote head No.1 error flag
SM231
Remote head No.2 error flag
SM240
Remote head No.1 reset flag
SM241
Remote head No.2 reset flag
System clock
The following table lists the special relay areas relating to the system clock.
No.
Name
SM400
Always On
SM401
Always Off
Fixed scan function information
The following table lists the special relay areas relating to the fixed scan function information.
No.
Name
SM480
Cycle overrun flag for inter-
module synchronization
SM488
Inter-module synchronization
error (out of synchronization
was detected on the remote
head module)
Data stored
Details
Off: Other than STOP state
This relay is turned on in STOP state.
On: STOP state
Off: Remote head No.n
• This relay is turned off when the remote head
normal
module of the remote head No.n is normal
On: Remote head No.n
(including minor error).
moderate/major error
• This relay is turned on when a moderate or
major error occurs in the remote head module
of the remote head No.n.
Off: Remote head No.n not
• This relay is turned off when the remote head
being reset
module of the remote head No.n is not being
On: Remote head No.n in
reset.
reset mode
• This relay is turned on when the remote head
module of the remote head No.n is being
reset (including the case when the remote
head module is removed from the base unit).
Data stored
Details
Always on
ON
OFF
Always off
ON
OFF
Data stored
Details
Off: No error for the inter-
• This relay is turned on during inter-module
module synchronization
synchronization when the I/O refresh,
(Normal)
intelligent function module refresh, and data
On: Error state for the inter-
transfer between the devices are not
module synchronization
completed within the inter-module
synchronization cycle.
• The ON state is maintained even after the
later processing is completed within the
specified inter-module synchronization cycle.
(Cleared by turning power off and on or
resetting).
Off: No error for the inter-
• This relay is turned on when the inter-module
module synchronization
synchronization signal cannot be identified
signal (Normal)
within the inter-module synchronization cycle
On: Error state for the inter-
specified in the parameter or more than one
module synchronization
signal has been identified within the same
signal
inter-module synchronization cycle.
• The ON state is maintained even after the
inter-module synchronization signal can be
later identified within the specified inter-
module synchronization cycle. (Cleared by
turning power off and on or resetting).
Set by (setting timing)
S (Status change)
S (Status change)
S (Status change)
Set by (setting timing)
Power-on to RUN or STOP
to RUN
S (Status change)
Set by (setting timing)
S (Status change)
S (Status change)
Appendix 3 List of Special Relay (SM) Areas
A
APPX
143