Dell iDRAC6 User Manual page 190

Remote access controller 6
Hide thumbs Also See for iDRAC6:
Table of Contents

Advertisement

Table 11-3. Serial Over LAN Configuration Advanced Settings
Setting
Character
Accumulate
Interval
Character Send
Threshold
NOTE:
If you change these values to lower values, the console redirection feature
of SOL may experience a reduction in performance. Furthermore, the SOL session
must wait to receive an acknowledgement for each packet before sending the next
packet. As a result, the performance is significantly reduced.
Table 11-4. Serial Over LAN Configuration Advanced Settings Buttons
Button
Print
Refresh
Apply
Go Back To Serial Over
LAN Configuration
Page
7 Configure SSH and Telnet for SOL at System→ Remote Access→
iDRAC6→ Network/Security tab→ Services.
NOTE:
NOTE:
by default.
190
Configuring and Using Serial Over LAN
Description
The typical amount of time iDRAC6 waits before sending a partial
SOL data packet. This parameter is specified in milliseconds.
Specifies the number of characters per SOL data packet. As soon
as the number of characters accepted by iDRAC6 is equal to or
greater than the Character Send Threshold value, iDRAC6 starts
transmitting SOL data packets that contain numbers of characters
equal to or less than the Character Send Threshold value. If a
packet contains fewer characters than this value, it is defined to be
a partial SOL data packet.
Description
Prints the Serial Over LAN Configuration Advanced
Settings values that appear on the screen.
Reloads the Serial Over LAN Configuration Advanced
Settings screen.
Saves any new settings that you make while viewing the
Serial Over LAN Configuration Advanced Settings screen.
Returns the user to the Serial Over LAN screen.
Each blade server supports only one active SOL session.
SSH protocol is enabled by default. Telnet protocol is disabled

Hide quick links: