Appendix; On-Site Cable Assembly And Installation; Cable Assembly Precautions - Huawei R240D Hardware Installation

Remote units
Hide thumbs Also See for R240D:
Table of Contents

Advertisement

R240D
Hardware Installation and Maintenance Guide

5.1 On-site Cable Assembly and Installation

5.1.1 Cable Assembly Precautions

Checking the Appearance of Cables
Checking the Appearance of Connectors
Precautions for Assembly
Issue 03 (2016-01-26)
If the cable jacket or insulation is visibly dirty, clean it before assembly.
If the jacket or insulation of a cable has visible damage, irreparable scuffing, or other
defects, do not use the cable.
If the shield layer of a cable is damaged, do not use the cable.
If the cable jacket or insulation cracks after the cable is bent or twisted, discard this cable
and check whether other cables have the same problem. If other cables have the same
problem, replace these cables.
Do not use connectors with visible defects, damage, rust or scuffing.
Do not use connectors if their shells or pins have exposed part or uneven plating, or their
pins are lost, broken, or bent.
Do not use connectors that have dirt on their pins or in their jacks or if there are
conductors between pins or between pins and the shell.
Use dedicated tools or tools delivered by Huawei and follow the methods given here
during assembly.
Hold terminals of cables instead of pulling the cables themselves when installing or
removing cable components.
Take the following precautions when cutting or stripping cables:
Make cables slightly longer than necessary.
Coil cables longer than 2 m (6.56 ft) after cutting. Bind and fasten the coils using
bundling ropes. The inner diameters of the coils should be larger than 20 times the
outer diameters of the cables.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.